background image

Applications

 

Primary Pressure Control 

Overpressure Protection (Monitor) 

Underpressure Protection 

(Standby) 

Relief Valve 

Backpressure Control 

Power Plant Type Applications* 

When Unique "Bleed to Pressure 

System" 

BPS

™ feature can be 

utilized 

Any large downstream systems 

(city gate stations, inter-system 
pressure limiting) 

Suction control to reciprocating 

compressors* 

Double-stage cut (working moni-

tor regulator* 

High Gain systems that require 

fast stroking speed (power plants, 
fertilizer plants)* 

Guidelines for Usage 

Large Volume Control Valve Actuators:

 

Control Valves that require large volume 
actuators may require Model VB-250 
Volume Boosters to ensure adequate 
stroking speed.  Volume Boosters are 
typically required for Becker RPDA and 
LPDA Series actuators size 12T or larger 
(2200 in

3

 

Bleed to Pressure System:

 The HPP-4 

Positioner is typically utilized for applica-
tions with a discharge pressures of 350 
psig or less in order to ensure adequate 
speed of operation.  Bleed to pressure 
system eliminates atmospheric emis-
sions by keeping discharge gas in the 
piping system. 

High Gain Systems:

 Power plant feeds 

and other similar systems require fast 
stroking speed in order to satisfy re-
quired “gain” of the system.  The VB-250 
Volume Boosters are applied based 
upon actuator size and required stroking 
speed. 
 

CVE Globe Pattern Control Valves:

 The  

Becker HPP series positioners are com-
patible with the Globe style control valve, 
but require a minimum of 2” of actuator 
stroke for proper feedback and opera-
tion.  This makes it impossible to use 
this positioner with most globe valves 
smaller than 4” port size. 

 

Compatible Actuators: 

Becker RPDA Actuators (Rotary Pis-
ton Double-Acting) 

Becker LPDA Actuators (Linear Pis-
ton Double-Acting) 

 

   Other manufacturer’s double-acting 

 

     piston actuators* 

 
*consult Becker for additional informa-
tion 

 

Retrofit Compatibility: 

Optimum performance is achieved by 
pairing the HPP-4 with genuine Becker 
control valve actuators.  Should you al-
ready have existing control valve actuator
(s) in service, the addition of a Model 
HPP-4 can improve performance and 
eliminate atmospheric bleed emissions if 
using the BPS (Bleed to a pressure sys-
tem) feature. 
Some Compatible Actuators: 

Bettis T-Series Piston Actuators 

Fisher Type 470 Piston Actuators 

Fisher Type 1061 Piston  

HPP-4 

September 1999 

HPP-4 Positioner 
Instruction Manual

 

Содержание HPP-4

Страница 1: ...of Construction 4 Accessories 4 Principals of Operation 5 Close on increasing 5 Open on increasing 6 Adjustment Procedure 7 Deadband Setting 8 Bias Adjustment 9 Range Adjustment 10 Section Page Chang...

Страница 2: ...n ac tuator The HPP 4 design positioner represents Becker s commitment to continuos development of new products and updating of existing products to maximize their performance while re taining simple...

Страница 3: ...High Gain Systems Power plant feeds and other similar systems require fast stroking speed in order to satisfy re quired gain of the system The VB 250 Volume Boosters are applied based upon actuator s...

Страница 4: ...Acting Close on loss of signal Connections All Ports N P T Action Direct and Reverse Acting Field reversible Performance Resolution 0 2 Hysteresis 1 0 Flow Capacity CV 1 5 Steady State Consumption See...

Страница 5: ...ts in the lower seat being pushed into the lower nozzle due to an imbalance in the beam forces At the same time the top seat moves away from the top nozzle This increases the pressure in the cylinder...

Страница 6: ...seat being pushed into the upper nozzle due to an imbalance in the beam forces At the same time the bottom seat moves away from the bottom nozzle This increases the pressure in the cylinder top while...

Страница 7: ...s im perative that adequate supply gas pres sure be supplied to the VRP CH in or der to ensure proper operation of the system and all accessories 2 Adjust the adjustable orifices The adjustable orific...

Страница 8: ...nce Pressure equations HPP 4 Discharge to PRESSURE SYS TEM NO Volume Boosters Pc Pd 0 4 Ps Pd Equation 1a HPP 4 Discharge to Atmosphere NO Volume Boosters Pc 0 4 Ps Equation 1 b Deadband Setting 1 Tur...

Страница 9: ...her rais ing the spring retainer or screwing the bias adjustment stud into the in dicator bar or tail rod Note the two jam nuts tightened against one an other to adjust the length of the stud When pro...

Страница 10: ...the HPP 4 starts valve movement until the end of the valve stroke and full pressure differential across the cylinder output gauges 1 After setting the bias for the start of the valve travel continue...

Страница 11: ...til the desired range provides full or zero output pressure 4 If the desired range is not achieved after making the above adjust ments readjust the bias per the previous instructions to allow proper r...

Страница 12: ...i tioner 2 Remove the range spring item 4 at both ends and those items connecting it to the rod item 23 and the posi 3 Remove the positioner from the bracket item 18 The tubing and fittings on each si...

Страница 13: ...tered before tightening the spring cartridge 3 For open on increasing positioner Remove the washer and jam nut from the adjusting screw in the bias spring Stroke Close on Increasing Open on Increasin...

Страница 14: ...e the positioner nozzles may not be adjusted properly See the adjust ment instructions to calculate the correct balance pressure Reduce the output pressures by turning the drum in the direction of inc...

Страница 15: ...send one cylinder output gauge to full power gas Refer to Procedure 7 note pages 9 Adjustment Procedure 6 __________ Check response of HPP 4 positioner Varying input signal 1 4 psig should produce cy...

Страница 16: ...gm 25 1213 11 12 13 1 8 Roll Pin SS 98 2950 14 8 32 x 1 SHCS 98 3144 15 Beam Block 25 1086 16 Outside piston 25 1018 17 3 16 x 1 2 Roll Pin SS 98 3089 18 1 4 20 x 2 1 2 HHCS 98 3180 19 Gauge Manifold...

Страница 17: ...HPP 4 Positioner Parts List HPP 4 17 September 1999...

Страница 18: ...HPP 4 Positioner Appendix HPP 4 18 September 1999...

Страница 19: ...HPP 4 19 September 1999 HPP 4 Positioner Appendix...

Отзывы: