Technical data
Rated voltage
230 V AC / 50 Hz
Switching current
5 A / 250 V AC at cos
=1
Power consumption
2 VA
Degree of protection
IP 20
Class of protection
(dependent on correct assembly)
II
Permissible ambient temperature
0 to +55 °C
Type of mounting
Flush mounted Ø 58 mm, wall moun-
ted/surface mounted in appropriate
surface mounted housing
What to do if...?
Problem
Cause
Remedy
Drive is not functioning.
Incorrect connection.
Check connection.
Drive is running in the
wrong direction.
Incorrect connection.
Swap over wire and
wire
on the power
supply unit.
The control unit does
not perform the external
commands.
The slide switch is set to
Manual mode.
Set the slide switch to
Automatic mode.
Alarm signal pending.
Wait for the alarm signal
to disappear or dismiss
it.
27 - en