What to do if...?
Problem
Cause
Remedy
Drive is not functioning.
Faulty connection.
Check the connection.
Drive moves in the
wrong direction.
Faulty connection.
Exchange
s
and
t
wires in the power
supply unit.
Automatic control com-
mands are not carried
out.
The sliding switch is set
to manual mode.
Set the sliding switch to
automatic mode.
The pre-set sunlight and
wind parameters cannot
be changed or are not
displayed.
No sensory equipment
is connected or the
connecting cable is
faulty.
Check the sensor
equipment, connecting
cable and connector
plug.
Curtain/canopy does not
move into the end limit
position.
1. Operating time is too
short.
2. End limit position is
not set.
1. Adjust operating
time accordingly via the
Function menu.
2. Set end limit position
in the LIGHT END LIMIT
or TIME END LIMIT
setting menu.
Wind alarm signal is
displayed although there
is no wind.
1. Line break
2. Gusts of wind
1. Check cable and
replace if necessary.
2. Wait approx.15
minutes.
Содержание Centronic SunWindSet SWS42
Страница 6: ...6 Montage und Betriebsanleitung Anzeigen und Tastenerklärung ...
Страница 7: ...fr en de nl 7 Montage Anschluss ...
Страница 30: ...30 Assembly and Operating Instructions Explanation of displays and buttons ...
Страница 31: ...fr en de nl 31 Assembly connection ...
Страница 54: ...54 Notice de montage et d utilisation Explication des textes d affichage et des touches ...
Страница 55: ...fr en de nl 55 Montage Branchement ...
Страница 78: ...78 Montage en gebruiksaanwijzing Verklaring van displays en toetsen ...
Страница 79: ...fr en de nl 79 Montage Aansluiting ...
Страница 100: ...4033 630 001 0c 04 08 309004 03 Becker Antriebe GmbH 35764 Sinn Germany www becker antriebe com ...