1
Technical data
Type
Unit
A100
Output torque
T
Nm
100
Output speed
n
min
-1
25
Diameter of hollow shaft
mm
25.4
Operating voltage
U
V
3~230 / 400
Frequency
F
Hz
50
Nominal current
I
A
4.6/2.6
Power factor
Cos
0.64
Cycles
*2)
1/h
6
Insulation material class
H
Thermoswitch
°C
170
Degree of protection
IP
54
Limit switch range
Revolutions
13
Static holding torque
Nm
450
On-site fuse protection
3x10 AT
Permissible ambient operating
temperature
°C
-20 to +40
Emission sound pressure level
dB(A)
≤ 70
Weight
*1)
(approx.)
kg
10
*1)
) With the LK version, the weight increases by approx. 0.5 kg.
*2
) A cycle is an opening and closing over the entire limit switch range at the full output torque as specified in the technical data.
The actual door cycles depend on the design, e.g. size and weight of the door.
Deviations are possible in structurally identical drives or special drives.
The information on the type plate always applies.
Subject to technical changes without notice.