Upper point to lower point
Put the transmitter into master mode.
Select the tubular drive by pressing the button until the tubular drive con-
firms.
All the following settings will then only be executed for this device.
There is no shading solution length adjustment with this limit
position setting.
Open to the desired upper limit position.
Press the programming button and, within 1
second, also press the UP button and hold the two
buttons down.
▻
The receiver confirms.
Then close to the desired lower limit position.
Press the programming button and, within 1
second, also press the DOWN button and hold the
two buttons down.
▻
The receiver confirms.
►
The limit positions are now set.
55 - en
Содержание 40340002300
Страница 6: ...Anzeigen und Tastenerkl rung 10 11 12 9 8 7 6 5 4 3 2 1 6 de...
Страница 35: ...35 de...
Страница 40: ...Explanation of displays and buttons 10 11 12 9 8 7 6 5 4 3 2 1 40 en...
Страница 67: ...67 en...
Страница 72: ...Description des affichages et des touches 10 11 12 9 8 7 6 5 4 3 2 1 72 fr...
Страница 104: ...Verklaring van aanduidingen en toetsen 10 11 12 9 8 7 6 5 4 3 2 1 104 nl...
Страница 130: ...130...
Страница 131: ...131...
Страница 132: ......