Function
The individual command is executed as a touch command (duration of com-
mand < 1 sec.) or as a maintained operation command (duration of command
> 1 sec.).
In combination with blinds, touch commands are executed as tilt commands.
The individual command is triggered by a standard series-parallel switch. The
individual command executes a travel command with a maximum duration of 3
minutes.
The central command is executed in dead man mode. The unit is controlled by
upstream control units, such as timers, sun protection controls etc. The con-
nection of an additional higher-ranking UC42/UC45 control unit enables exe-
cution of the central command in maintained operation. Optionally, various
group commands can be formed by connecting further higher-ranking UC42/
UC45 control units.
Incoming commands are executed in the following order:
1. Central command UP
2. Central command DOWN
3. Individual command UP
4. Individual command DOWN