background image

EN

DOC-703-INTBM REV01

USER MANUAL

Central Vacuum System

Содержание Platinum Series

Страница 1: ...EN DOC 703 INTBM REV01 USER MANUAL Central Vacuum System ...

Страница 2: ... REV01 ORIGINAL INSTRUCTIONS TABLE OF CONTENT INTRODUCTION 3 IMPORTANT SAFEGUARDS 4 GROUNDING INSTRUCTIONS WARNING 5 INSTALLATION 6 HOW TO USE 7 LCD INSTRUCTION 8 MAINTENANCE 12 TROUBLESHOOTING 13 SERVICE INFORMATION 14 ...

Страница 3: ...anual carefully prior to use Then enjoy cleaner healthier living and years of trouble free performance For more information on BEAM Central Vacuum Systems and other innovative BEAM products visit beamvac com Components of a BEAM Central Vacuum System Power Unit Dust Collection Receptacle Mounted in the utility room basement or garage it removes dust dirt and allergens from living areas Tubing Dust...

Страница 4: ...grounding instructions Do not use extension cords or outlets with inadequate current carrying capacity Turn off all controls before unplugging Do not unplug by pulling on the cord To unplug grasp the plug not the cord Do not handle plug or cord with wet hands Do not put any object into openings Do not use with any openings blocked keep free of dust lint hair and anything that may reduce airflow Th...

Страница 5: ...ized dealer distributor DO NOT OIL THE MOTOR AT ANY TIME IT IS PERMANENTLY LUBRICATED AND SEALED Rating Plate The model type and serial numbers are indicated on the rating plate located on the control panel or motor hood For prompt and complete service information always refer to these numbers when inquiring about service GROUNDING INSTRUCTIONS WARNING WARNING This appliance must be grounded if it...

Страница 6: ...pect the power unit A typical location would be in a garage where you could vacuum your car or garage area and where emptying the dirt receptacle and cleaning the filter would be more convenient Other suitable locations are in the basement laundry room or ventilation storage room Install Power Unit You are now ready to install the power unit Be sure the power unit will be located at least 30 cm fr...

Страница 7: ...he following operating levels AC voltage current draw and circuit board temperature If the voltage is below or above standard operating voltage high current draw or locked rotor the power unit will not operate In this case the LED next to the On Off button will blink or go out until the problem ceases In the event any one of these problems happening make sure all low volt switches are in the OFF p...

Страница 8: ... Enter button Temperature Customization Use the Left and Right toggle buttons to select the temperature format of either C or F Once the correct format has been selected press the Enter button to proceed to the next screen Time Format Customization Use the Left and Right toggle arrows to select the temperature format of either 12 hour or 24 hours Once the correct format has been selected press the...

Страница 9: ...he power unit motor is operating at peak or optimum performance when all five power bars are illuminated Normal operating performance is when three to five bars are shown Performance levels will decrease as the filter is loaded with debris or as the motor has significant wear Fewer bars will be illuminated as performance decreases When the power unit is off the display will illuminate the airflow ...

Страница 10: ... and possibly emptying the bucket press the Enter button to return to the Main Screen This will reset the timer for the bucket monitor Empty Flashing Power Bars with Sad Face This screen is displayed when the power unit motor is unable to operate at optimal system performance When only 2 bars or less are illuminated the airflow is restricted meaning the vacuums cleaning power has decreased If the ...

Страница 11: ... to automatically reset the display will switch to the Phone Icon with a Sad Face screen indicating the need to contact a Beam dealer for service This indicates a motor failure where service is needed Phone Icon with Sad Face This screen will be displayed for either of two reasons 1 The system experiences a failure that requires repairs by an authorized Beam service technician 2 The power unit rea...

Страница 12: ...ectrical outlet before removing the dirt receptacle 1 Remove the dirt receptacle 2 Wrap a large plastic bag around the lower portion of the power unit and hold firmly in place 3 Grasp the sewn in weight at the bottom of the filter through the plastic bag Shake vigorously Dirt will fall into the bag 4 Carefully remove the bag from the unit Place the empty dirt receptacle on the power unit Cleaning ...

Страница 13: ...e upper cylinder Total Loss of Suction with motor running 1 Check the hose for obstruction 2 Turn on the power unit with the on off button and follow the same procedure as in step 2 above However with a total loss of suction at all inlets if the problem is a clog in the system it would be located between the power unit and first inlet Motor Refuses to Start 1 Check fuses or breakers trip switches ...

Страница 14: ...et serve as a guide for routine operation and maintenance For more information contact your local authorized dealer distributor Service Warranty Warranty service is managed by your local authorized dealer distributor Sold and serviced by 2020 01 9 For additional product information visit beamvac com ...