WIRING Diagram 3

Electrical Connections

CAUTION! For Supply Connections, use wires suitable for at least 194° F (90° C).

3.

     A shaded pole motor is used to drive the Twin-Flo 

III 

blower on 115 -120 V. 60 hz.  Since current drain is 

very small, wiring codes for short circuit protection only will apply.  The motor is connected in series with a 
normally open aquastat in contact with the heating element.  Therefore, the blower runs only when unit is suffi -
ciently hot and the switch is in the "min" or "max" position (not "off").  A ground screw is supplied with all units.
     Electrical connections are to be made to all units following the diagrams below.  Choose the diagram that 
best suits your application.    
     Since the blower runs on all Twin-Flo 

III 

models only when the system circulator pumps hot water through 

the unit, simply connect it to the 115 V line.  The blower then starts after a short warm-up, and stops a few 
minutes after the circulator shuts off (see diagram #1).
     Adding a line voltage type room thermostat will permit the setting of a maximum room temperature (see 
diagram #2). This 'T' stat will only operate the kickspace unit. If the circuit or system circulator is not running, 
the kickspace heater will not operate.
     

All electrical connections must conform to local and national codes.

     

Connection through a circulator or zone auxiliary switch may also be used to permit instant shutdown of the   

 blower as the circulator stops (see diagram #3).

K-42

K-84

K-120

1 GALLON

2 GALLONS

3 GALLONS

.

50

.50

.74

.17'

.8'

1.2'

53

103

127

30.7

30.7

66.8

.22'

.95'

1.5'

AMP

K42

CFM (HIGH SPEED)

MOTOR INFORMATION

FRICTION LOSS (HEAD)

3200

3200

3200

.43'

1.45'

2.97'

.034

.034

.068

115

115

115

WATT

K84

VOLTAGE

RPM

K120

HP

MIN

MAX

T-STAT

(NEUTRAL)

L2

(GND)

WIRING DIAGRAM 1

GREEN SCREW

115/1/60

LINE IN

L1

BLUE

(HOT)

SPDT

2

1

3

BLOWER

WHT

MOTOR

BLK

RED

115V LINE

CAT-68252-A

BLUE

OFF

WIRING DIAGRAM 2

LINE VOLT

ROOM T’STAT

R

W

MIN

MAX

T-STAT

(NEUTRAL)

L2

(GND)

GREEN SCREW

115/1/60

LINE IN

L1

BLUE

(HOT)

SPDT

2

1

3

BLOWER

WHT

MOTOR

BLK

RED

115V LINE

CAT-68253-A

BLUE

OFF

Содержание twin-floIII

Страница 1: ...loor level and check piping and wiring locations The air outlet should be facing but not extending beyond the toe space riser at the opening The air outlet should also be located at the bottom portion...

Страница 2: ...TWIN FLO III TYPE K42 FIGURE A 2 TWIN FLO III TYPE K84 FIGURE B TWIN FLO III TYPE K120 FIGURE C Dimensions shown in English and metric...

Страница 3: ...mply connect it to the 115 V line The blower then starts after a short warm up and stops a few minutes after the circulator shuts off see diagram 1 Adding a line voltage type room thermostat will perm...

Страница 4: ...his case it will collect on the rotor blades and air passage of the unit Regular cleaning with a vacuum cleaner tool is advised with fre quency determined by prevailing conditions Always make sure tha...

Страница 5: ...em and create a pressure drop towards the supply tee forcing water up into the unit The arrow on the tee should point in the direction of water flow Figure 2 Figure 1 cutaway Figure 2 cutaway A ventur...

Страница 6: ...ble solutions a Water is not hot enough Check system water temp If radiant system low temperature aquastat may be needed b Water not circulating fast enough Kickspace heaters must have at least 1GPM f...

Страница 7: ...valve Do not return to bottom drain tapping Operation from steam boiler water is entirely possible as long as supply and return connection is installed be low level of water line on a steam boiler Thi...

Страница 8: ...any workmanship of any installer of the Product This limited warranty is conditional upon a shipment to the Manufacturer of that part of the Product thought to be defective Goods can only be returned...

Отзывы: