INSTALLATION INSTRUCTIONS  •  TYPE K

TFII-14

J17-63967

Beacon/Morris

TWIN-FLO

III

®

 

HEATER

GENERAL DESCRIPTION

TWIN-FLO 

III 

heaters are for use with forced hot water residential heating systems and consist of a copper tube, 

aluminum fi nned heating element, with an electric motor and blower of unique cross fl ow design. Their purpose is to 
deliver a comfortable stream of warmed air, at or near fl oor level, and their construction is extremely compact so minimum 
space is required for installation. The type K heater is primarily used in horizonal fl oor installation, for example: under a 
kitchen counter cabinet, or bathroom sink enclosure. They are ideal for radiant systems with the use of a low temperature 
aquastat designed to turn the unit on at 110° F. Type W is for vertical mounting, fully recessed in the wall studs, with the 
air discharged upward through a fl ush mounted, louvered front panel. Type F is a surface mounted wall unit, with the 
air discharged evenly through a louvered front panel in an upward direction. All types have heating elements with 1/2" 
nominal (5/8 O.D.) copper tube connections, and 115V. electric blower motor, interwired with a 120° F (49° C) reverse 
acting aquastat that prevents operation until hot water is circulating. These units are 

NOT

 intended to be used on one or 

two pipe steam systems. See bottom of page 5. For gravity fed systems, it is recommended that a separate circulator pump 
be installed for the kick space heater.

INSTALLING TWIN-FLO 

III

 TYPE  K

1.

   Select a location under the bottom shelf of a cabinet that meets the minimum dimensions shown in Fig. A.

2.

  

 CUT AN ACCESS PANEL THROUGH THE BOTTOM OF THE CABINET AT THIS LOCATION, LARGE ENOUGH 

FOR INSTALLATION AND SERVICE. IT IS RECOMMENDED THAT THIS ACCESS PANEL BE CONSTRUCTED SO 
ANNUAL CLEANING OF THE BLOWER FAN AND COIL FINS CAN BE EASILY ACCESSIBLE.

3.   At this location, center and cut an opening in the toe-space riser 4'' high x 11'' long (model K42) (See fi gure A) 

or 4'' high x 18'' long (model K84)  (See fi gure B) or 4" high x 23" long (Model K120). (See fi gure C).

4.   Set the TWIN-FLO 

III

 in the space at fi nished fl oor level 

and check piping and wiring locations.  The air outlet 

should be facing but not extending beyond the toe-space riser at the opening. The air outlet should also be located at 
the bottom portion of the 4'' toe-space riser (See fi gure A) at fi nished fl oor level. Make sure the switch is accessible 
through the grille openings. The front of the unit should fi t fl ush to the inside of the toe space riser.

5.

   Install the grille over the 4'' toe-space opening with the two screws provided.  

6.

   If using the TWIN-FLO "Easy Connect" Flexible Hose Connection Kit, see those installation instructions.

7.

   Next, prepare the heating element for pipe connections (this procedure will also pertain to Model types W and F).  

Remove the 3 screws from the electric conn. box. Unsnap (pull) the thermostat clamp from the return copper U-bend.  
Holding down the top cover, remove the 4 element cover screws. Carefully remove this top cover noting the position of 
the element and the neoprene side pad. Lift out the element for soldering and fi ttings. Both ends are sized to accept   
1/2'' solder fi ttings. (Note required fi ttings for one pipe and two pipe systems on page 6).

8.

   Replace the heating element in the bottom cover in the proper position. Place the neoprene side pad in position and 

replace the top cover using the 4 screws. Tighten enough to keep the element in place between the covers. DO NOT 
OVER-TIGHTEN!

9.

   Place the TWIN-FLO 

III 

under the cabinet and connect the piping and wiring. 

Make sure unit & outlet are free of

 

any 

dirt or debris prior to start up.

 Turn on the system, purge of air, check blower operation and check for any possible 

leaks in the piping (run for 2 hrs. minimum). It should then be screwed to the fl oor through the four resilient mounting 
feet (2-inside electrical box and 2 external). Do not over-tighten screws. Secure top of electrical box.

ATTENTION: READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL, OPERATE, OR SERVICE 
THE BEACON MORRIS TWIN-FLO 

III 

HEATERS! RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.

INSPECT THE SHIPMENT IMMEDIATELY WHEN RECEIVED TO DETERMINE IF ANY DAMAGE HAS OCCURRED 
DURING SHIPMENT.

PRIOR TO INSTALLATION, CHECK FOR ANY VISIBLE DAMAGE.  MAKE CERTAIN THAT ANY LOOSE PARTICLES 
ARE REMOVED (ESPECIALLY IN THE BLOWER ASSEMBLY AREA).
SAFE TO USE WITH POTABLE WATER.

8/11

Содержание twin-floIII

Страница 1: ...loor level and check piping and wiring locations The air outlet should be facing but not extending beyond the toe space riser at the opening The air outlet should also be located at the bottom portion...

Страница 2: ...TWIN FLO III TYPE K42 FIGURE A 2 TWIN FLO III TYPE K84 FIGURE B TWIN FLO III TYPE K120 FIGURE C Dimensions shown in English and metric...

Страница 3: ...mply connect it to the 115 V line The blower then starts after a short warm up and stops a few minutes after the circulator shuts off see diagram 1 Adding a line voltage type room thermostat will perm...

Страница 4: ...his case it will collect on the rotor blades and air passage of the unit Regular cleaning with a vacuum cleaner tool is advised with fre quency determined by prevailing conditions Always make sure tha...

Страница 5: ...em and create a pressure drop towards the supply tee forcing water up into the unit The arrow on the tee should point in the direction of water flow Figure 2 Figure 1 cutaway Figure 2 cutaway A ventur...

Страница 6: ...ble solutions a Water is not hot enough Check system water temp If radiant system low temperature aquastat may be needed b Water not circulating fast enough Kickspace heaters must have at least 1GPM f...

Страница 7: ...valve Do not return to bottom drain tapping Operation from steam boiler water is entirely possible as long as supply and return connection is installed be low level of water line on a steam boiler Thi...

Страница 8: ...any workmanship of any installer of the Product This limited warranty is conditional upon a shipment to the Manufacturer of that part of the Product thought to be defective Goods can only be returned...

Отзывы: