background image

 

 

7

 

Beach House – Water Filter Systems, Ring, Clonakilty, Co. Cork, Ireland

 

 

Activation, Maintenance, Filter Change 

 

 

Activating the System for the first time 

Make  sure  all  water  supply/drain  lines  are 
secure and free from leakage. 
Open  the  water  supply.  If  you  are  using  the 
self-piercing valve, slowly turn the saddle valve 
counter clockwise until fully open. Check stem 
seal for leakage. If necessary tighten stem nut 
lightly. 
Turn  storage  tank  valve  one  quarter  turn 
counter clockwise to open the valve (the  

 

handle should be in line with the tubing as 
it enters the connection). 
Open the product water faucet and let the 
water  flow  until  all  the  air  has  been 
expelled  from  the  system.  This  will  take 
about an hour. 
Close  the  product  water  faucet.  In  30 
minutes,  check  the  connections  for  leaks 
and correct if necessary.

 

 

 
 
 
 
 
 
 
 

 

 

Maintenance 

For the best quality water, it is essential to change the filters regularly. Changing the filters is 
easy (see description below).  

 

Filter 

Recommended exchange 

Stage 1: 5 Micron Spun Sediment Filter  

 

 

6 month to 1 year  

Stage 2: Activated Carbon Filter 

 

 

6 month to 1 year  

Stage 3: 1 Micron Spun Sediment Filter 

 

 

6 month to 1 year  

Stage 4: Membrane 

 

 

3-5 years (depending on TDS) 

Stage 5: Post Carbon Filter 

 

 

+/- 1 year 

Stage 6: Bacteria & Virus Filter 

 

 

+/- 2 years 

 
 

 

When you go on holiday 

If you go on holiday for longer than 3 weeks it is advisable to remove the membrane 
for the duration of your absence. To do this, proceed as follows: 
 

1.  Switch off feed supply under the sink.  
2.  Empty tank and switch off tank. 
3.  Detach tube to membrane housing cap. 
4.  Screw  off  cap  and  remove  membrane.  Take  care  not  to  touch  membrane  with  your 

hands, latex gloves are recommended. 

5.  Place membrane in a Ziploc type freezer bag and place bag in the fridge. 
6.  DO NOT PLACE BAG IN THE FREEZER! 
 

Do not use the first two Reservoirs of Water 

Allow  the  reservoir  to  fill  for  4-6  hours.  Dispense  this  water  to  drain.  This  process 
removes the factory installed sanitizing solution from the entire system and sends it 
to the drain. Repeat this process one more time. Allow the tank to fill for 4-6 hours 
and dispense this water to the drain.  

Содержание Reverse osmosis drinking water system

Страница 1: ...Installation Service Guide Lo call Ireland 1890 20 30 20 International 00353 23 88 58 000...

Страница 2: ...re a successful installation and reliable operation Routine maintenance is essential to the longevity and performance of the system Filters should be changed every six to twelve months depending on th...

Страница 3: ...3 Beach House Water Filter Systems Ring Clonakilty Co Cork Ireland System Faucet Diagrams 1 Sediment Filter 5mic white clear housing 2 Carbon Filter 3 Sediment Filter 1mic white...

Страница 4: ...might come in contact with hot water pipes or other hazards Determine the location for the faucet Check to see that drilling the faucet hole will not damage pipes or wires running underneath the sink...

Страница 5: ...s any other than described here acorn alkathine etc then you must first buy the appropriate connections at your local Hardware store Installing the Drain Clamp Select a location for the drain hole bas...

Страница 6: ...stall the star lock washer and nut then tighten firmly while aligned faucet in the desired direction Additional Point of Use Connection To connect an additional point of use icemaker extra faucet etc...

Страница 7: ...r Recommended exchange Stage 1 5 Micron Spun Sediment Filter 6 month to 1 year Stage 2 Activated Carbon Filter 6 month to 1 year Stage 3 1 Micron Spun Sediment Filter 6 month to 1 year Stage 4 Membran...

Страница 8: ...er pressure If line pressure is below 30 psi install a booster pump Not enough water Water supply is blocked Clear restriction rotate valve on feed water Not enough water Storage tank is depleted Cons...

Отзывы: