BEA VIO-ST Скачать руководство пользователя страница 4

2

1

4

5

1
2

1

1
2

1
2

1
2

1
2

1

1
2

1
2

1

1

1

1
2

BEA SA | LIEGE Science Park | ALLÉE DES NOISETIERS 5 - 4031 ANGLEUR [BELGIUM] | T +32 4 361 65 65 | F +32 4 361 28 58 | [email protected] | WWW.BEA-SENSORS.COM

©

BE

A

 

 | 

O

ri

gi

na

l i

ns

tr

uc

ti

on

s

 |

 

4

2

.7

75

3 / V

4

 -

 1

0.

16

BEA hereby declares that the VIO-ST is in conformity with the basic requirements and the other relevant provisions of the 
directives 2014/30/EU, 2006/42/EC and 2011/65/EU.
Notified Body for EC inspection: 0044 - TÜV NORD CERT GmbH, Langemarckstr. 20, D-45141 Essen
EC-type examination certificate number: 44 205 13 089601-001
Angleur, April 2016 

Pierre Gardier, Authorized representative and responsible for technical documentation

The complete declaration of conformity is available on our website.

LED-SIGNALS

Only for EC countries: According to the European Guideline 2012/19/EU for Waste Electrical and Electronic Equipment (WEEE)

PL

EA

SE K

EE

P F

O

R F

U

R

TH

ER U

SE - D

ES

IG

N

ED F

O

R C

O

LO

U

R P

R

IN

TI

N

G

The ORANGE LED 
flashes 1 x.

The ORANGE LED 
flashes 2 x.

The ORANGE LED 
flashes 4 x.

The ORANGE LED 
flashes 5 x.

The ORANGE LED 
is on.

The RED LED flashes 
quickly after an 
assisted setup.

The RED LED 
lights up 
sporadically.

The LED is off.

The reaction of 

the door does not 

correspond to the 

LED-signal.

The ORANGE LED 
flashes quickly.

The sensor signals 
an internal fault.

Irregularities in the 
power supply

The sensor receives 
not enough IR-energy.

The sensor receives 
too much IR-energy.

The sensor encounters 
a memory problem.

The sensor vibrates.

The sensor sees the door 
during the assisted setup.

The sensor sees the door.

The sensor is disturbed by 
lamps or another sensor.
The sensor is disturbed 
by the rain.

A DIP-switch was changed 
without confirmation.

Check power supply.
Check wiring.

Use the 1 m prism if possible (accessory). 
Check the angle of the IR-curtains.

Cut and restore power supply.  
If orange LED lights up again, replace sensor.

Check the angle of the IR-curtains.
Launch a new assisted setup.

Attention: Do not stand in the detection field!

Change the output configuration (DIP 4).

Use a low energy prism if possible (accessory). 
Check the angle of the IR-curtains.

Check if the sensor is fastened firmly.
Check position of prism and cover.

Choose a different frequency (DIP 2).

Choose the critical environment presetting (DIP 1).

Launch an assisted setup and adjust the IR angle.

Cut and restore power supply.
If orange LED flashes again, replace sensor.

Check connections to test output.
If your door controller is not able to test the sensor, 
connect the red and blue cable to the power supply.*

Confirm the DIP-settings by a long push on the 
push button.  

*excludes EN 16005-conformity of the door system

Содержание VIO-ST

Страница 1: ...x contact voltage 42 V AC DC 0 3 s to 1 s not adjustable Typical 5 ms 12 V 30 V DC 5 10 to be operated from SELV compatible power supplies only 1 6 W 1 8 m to 3 m 1 V Log L 10 V Log H max 30 V 25 C to 55 C IP54 70 dB 20 years EN 62061 SIL2 EN 61496 1 ESPE Type 2 EN 61000 6 2 EN 61000 6 3 EN 12978 EN 50581 EN 16005 EN ISO 13849 1 Pl c CAT 2 under the condition that the door control system monitors ...

Страница 2: ...door control unit and the door cover profile must be correctly earthed SENSOR H W 2 20 m 2 30 m 2 50 m 2 55 m 3 00 m 2 80 m H W 2 20 m 1 20 m 2 50 m 1 40 m 3 00 m 1 60 m 2 2 m Depth of curtain 8 10 cm Depth of safety field 25 cm RELAY R1 RELAY R2 12 30 V DC Check position of IR curtains with Spotfinder and adjust if necessary DOOR Detection field width indicated according to conditions defined in ...

Страница 3: ...aving the premises The manufacturer of the door system is responsible for carrying out a risk assessment and installing the sensor and the door system in compliance with applicable national and international regulations and standards on door safety and if applicable the machinery directive 2006 42 EC The device cannot be used for purposes other than its intended use All other uses cannot be guaran...

Страница 4: ...ED signal The ORANGE LED flashes quickly The sensor signals an internal fault Irregularities in the power supply The sensor receives not enough IR energy The sensor receives too much IR energy The sensor encounters a memory problem The sensor vibrates The sensor sees the door during the assisted setup The sensor sees the door The sensor is disturbed by lamps or another sensor The sensor is disturb...

Отзывы: