3

VIO-ST

4

+

+

A

B

Launch an 

ASSISTED SETUP

 to verify wiring, position of the 

curtains and correct functioning of the sensor.

SETTINGS 

(by DIP-switch)

QUICK SETUP

ASSISTED SETUP

SETUP

OPEN+CLOSE

RED-GREEN

OFF

RED-GREEN

OFF

Step outside of the detection field before launching a setup.

LONG (> 3s)

LONG

SHORT

standard

critical

environment

standard

extreme 

1

1

  Enhanced IR-immunity which excludes EN 16005-conformity of the door system.

LONG (> 3s)

critical environment

: enhanced immunity for critical environments (rain, snow, lamps...). Only 1 IR-curtain activated.

standard

: standard environments (factory setting)

NC

NO

The yellow and white wires have to be connected to launch an 

assisted setup.

After changing a DIP-switch, the orange LED flashes. 

A LONG push on the push button confirms the setting.

Always launch a setup after changes of the DIP-settings.

- Test the good functioning of the installation before leaving the premises.

- The manufacturer of the door system is responsible for carrying out a risk assessment and installing the sensor and the door system 

  in compliance with applicable national and international regulations and standards on door safety and if applicable, the machinery  

  directive 2006/42/EC. 

- The device cannot be used for purposes other than its intended use. All other uses cannot be guaranteed by the manufacturer 

  of the sensor.  

- The manufacturer of the sensor cannot be held responsible for incorrect installations or inappropriate adjustments of the sensor. 

- Only trained and qualified personnel may install and setup the sensor. 

- The warranty is void if unauthorized repairs are made or attempted by unauthorized personnel. 
- Avoid touching any electronic and optical components, avoid vibrations, do not cover the sensor and avoid proximity to 
  neon lamps or moving objects.

- It is recommended to clean the optical parts at least once a year or more often if required due to environmental conditions.

SAFETY INSTRUCTIONS

PRESETTINGS

ENVIRONMENT

R2 CONFIGURATION

FREQUENCY

ORANGE

OFF

Содержание VIO-ST

Страница 1: ...x contact voltage 42 V AC DC 0 3 s to 1 s not adjustable Typical 5 ms 12 V 30 V DC 5 10 to be operated from SELV compatible power supplies only 1 6 W 1 8 m to 3 m 1 V Log L 10 V Log H max 30 V 25 C to 55 C IP54 70 dB 20 years EN 62061 SIL2 EN 61496 1 ESPE Type 2 EN 61000 6 2 EN 61000 6 3 EN 12978 EN 50581 EN 16005 EN ISO 13849 1 Pl c CAT 2 under the condition that the door control system monitors ...

Страница 2: ...door control unit and the door cover profile must be correctly earthed SENSOR H W 2 20 m 2 30 m 2 50 m 2 55 m 3 00 m 2 80 m H W 2 20 m 1 20 m 2 50 m 1 40 m 3 00 m 1 60 m 2 2 m Depth of curtain 8 10 cm Depth of safety field 25 cm RELAY R1 RELAY R2 12 30 V DC Check position of IR curtains with Spotfinder and adjust if necessary DOOR Detection field width indicated according to conditions defined in ...

Страница 3: ...aving the premises The manufacturer of the door system is responsible for carrying out a risk assessment and installing the sensor and the door system in compliance with applicable national and international regulations and standards on door safety and if applicable the machinery directive 2006 42 EC The device cannot be used for purposes other than its intended use All other uses cannot be guaran...

Страница 4: ...ED signal The ORANGE LED flashes quickly The sensor signals an internal fault Irregularities in the power supply The sensor receives not enough IR energy The sensor receives too much IR energy The sensor encounters a memory problem The sensor vibrates The sensor sees the door during the assisted setup The sensor sees the door The sensor is disturbed by lamps or another sensor The sensor is disturb...

Отзывы: