BEA SUPERSCAN-T Скачать руководство пользователя страница 3

 

75.5911.02 20180226 

 

Page 3 of 9 

 

5. 

Mark and drill the extrusion (in the approximate locations as shown below) where the mounting holes (one at each end) should 
be located.  Also, be sure to mark and drill the proper end for an additional hole to be used for wire passage.  Wire passage 
hole should be approximately ¼” diameter.  Screw mount holes only serve as a pilot hole for ease of installing the self-drilling 
screws that are provided. 

 
 
 
 
 
 
 

NOTE:  

Take care to avoid screw holes near the seams of the door.  It may be difficult to drill and install a screw, and may 

possibly damage the inside structural braces of the door. 

 

6. 

Hold the SuperScan-T back up to the door at the pre-drilled location and attach the unit to the door with the 2 screws provided.  Ensure that the 
SuperScan-T extrusion is tight against the door. 

 
 
 
 
 
 
 
 

 

7. 

If SuperScan-Ts are to be mounted on both sides of the door, a wire passage hole will be required through the door to go from the approach 
side to the safety side, as shown below.  Again, be sure not to drill through any through-bolts or braces within the door.  A The extension wire 
going between the terminal blocks should be approximately 18” long and can then be cut back as needed.  

 
 
 
 
 
 
 
 
 

 

8. 

Next, a wire passage hole will be required in the door header (image below, left) and also in the jamb tube (image below, right) at approximately 
the same height as the SuperScan-T.  The wire transfer hole in the jamb should be at the secure side of the door.  Normally, this will be the 
interior side.  Feed the wire through the jamb tube up to the header. Ensure that enough wire is left out to reach the SuperScan-T terminal block. 

 
 
 
 
 
 
 
 
 
 
 
 

NOTE:  

Ensure that there is enough slack in the cabling to allow for adequate movement of the cable throughout the range of door travel. 

 

9. 

Once all cabling is in place, the plastic sheath must be installed over the wire coming out of the jamb tube.  This must be done before making 
final connection to the terminal block.  The sheath may have to be cut to fit the application.  Once the wire is fed though, the plastic cap may be 
installed on the jamb, over the transfer hole.  

 

 
 
 
 

 

 
 

 

 

 

 

 

Plastic ribbed sheath 

MECHANICAL 
INSTALLATION 
 
PREPARING AND 
MOUNTING THE 
SENSOR 

Содержание SUPERSCAN-T

Страница 1: ...rupts the angle DESCRIPTION SPECIFICATION Power Supply 12 24 VAC VDC 10 Current Consumption Master On 60 mA max Off 30 mA max Slave On 40 mA max Off 30 mA max Inhibit Input 12 24 VAC VDC 10 inhibited when voltage is applied Monitoring Request Input 12 35 VDC required polarity sensitive Min pulse width duration 50 ms Output Interface relay Relay max contact rating is 1A 30v resistive Detection Rang...

Страница 2: ...simply pull the tab out away and downward from the extrusion then rotate the module out from extrusion image below right To re install simply reverse the procedure The PCB must first be installed into the adjustment clip then installed into the aluminum extrusion IMPORTANT NOTE The end of the extrusion that is towards the pivot end of a center hung door should be in far enough from the edge of the...

Страница 3: ...below Again be sure not to drill through any through bolts or braces within the door A The extension wire going between the terminal blocks should be approximately 18 long and can then be cut back as needed 8 Next a wire passage hole will be required in the door header image below left and also in the jamb tube image below right at approximately the same height as the SuperScan T The wire transfer...

Страница 4: ...the opposite end until all mechanical adjustments have been completed Refer to the appendices of this document for various wiring schematics Terminal Explanation of Wiring Connections 1 Test input when used as a monitored sensor positive when utilizing monitoring 2 Ground negative when utilizing monitoring Negative terminal if Input inhibition is used 3 Input inhibition All detection is ignored In...

Страница 5: ...tector will remain active thereby causing the door to stay open or to not open This fail safe operation will cause the door to be inoperative in the automatic mode since there will be a constant signal either to the safety input or to the activation input of the door control depending on which module is sensing detection If an extremely IR absorbent floor is present set J1 to Background Analysis m...

Страница 6: ...nded for use without Slave modules added to the chain and is for Master only operation The jumper is located at the Output end of the Master module Master only has jumper installed on two pins closest to center of board With jumper J4 installed as shown in the image to the right middle the Master is intended for Slave modules to be added Jumper J4 is also installed on the last Slave module in the ...

Страница 7: ... below to help determine the angling The angles may have to be altered once the units have been powered up and walk tested INACTIVE ZONE B DISTANCE FROM FLOOR SUPERSCAN T ANGLE 0º 5º 10º 15º 20º 25º 8 0 6 12 19 26 33 12 0 6 12 18 24 31 16 0 5 11 16 23 29 20 0 5 10 16 21 27 Approach Side Safety Side Hinge Side Leading Edge Side Slave module Master module Door Cord must be placed on interior of door...

Страница 8: ...d non monitoring modules in the same chain observe the following rules Non monitoring Master modules CANNOT be used with monitoring Slave modules All other combinations will work however for a system to utilize monitoring all modules must be monitoring modules PROBLEM POSSIBLE CAUSE CORECTIVE ACTION SuperScan T does not work at all No LED indications Faulty power supply Faulty connections Power su...

Страница 9: ...mpliance issue is noted The equipment should be inspected annually in accordance with the minimum inspection guidelines A safety check that includes at a minimum the items listed on the safety information label must be performed during each service call If you are not an AAADM certified inspector BEA strongly recommends you have an AAADM certified inspector perform an AAADM inspection and place a ...