  The sensor must be firmly 

fastened to prevent vibration. 

q

  Sensor must be in a location that does 

not interfere with door hardware (finger 
guards, lock rods, etc.). 

q

  The sensor must not have any 

unwanted objects likely to 
move or vibrate in its path. 

 
 

1. 

Remove the screw that secures the endcap to the SuperScan-T extrusion (image below, left). 

 

 
 
 
 
 
 

 
 

2. 

Remove the plastic lens by pulling the lens out from the top of the extrusion (image above, right).  Do not use a screwdriver to pry the lens, as 
cracking may occur. 

 

CAUTION!

 

REMOVE THE MASTER AND ALL SLAVE CIRCUIT BOARDS FROM THE ALUMINUM EXTRUSION 
BEFORE PERFORMING ANY DRILLING. 

WHEN COMPLETE, ENSURE THAT ALL METAL SHAVINGS ARE CLEANED FROM THE EXTRUSION 
BEFORE RE-INSERTING THE CIRCUIT BOARDS. 

 

3. 

The image  below (left) shows the  angle  adjustment clip  in its  proper position within  the  extrusion (PCBs removed and clip shown  at  end  of 
extrusion for clarity only).  To remove the clip, simply pull the tab out away and downward from the extrusion, then rotate the module out from 
extrusion (image below, right).  To re-install, simply reverse the procedure.  The PCB must first be installed into the adjustment clip, then installed 
into the aluminum extrusion.  
 

 
 
 
 
 
 
 
 
 
 
 
 

 
IMPORTANT NOTE:   The end of the extrusion that is towards the pivot end of a center-hung door, should be in far enough from the edge of 
the  door  (image  below,  left)  to  prevent  the  endcap  of  the SuperScan-T  from  rubbing  against  the  finger  guard  during  door  movement.    Pay 
particular attention on the safety side of the door.  Hinge-hung doors will not require as much clearance between the end of the SuperScan-T 
and hinge-side jamb (image below, right).  At the leading edge of the door, the edge of the SuperScan-T, including the endcap, should be as 
close as possible to the leading edge of the door, without creating mechanical interference with the door jamb or with an adjacent door (pairs). 

 
 
 
 
 
 
 
 
 
 
 

4. 

Hold the SuperScan-T extrusion up to the top of the door. Ensure that the extrusion is oriented correctly.  
 

 

 

 

 

 
 

 

MECHANICAL 
INSTALLATION 
 
PREPARING AND 
MOUNTING THE 
SENSOR 

INSTALLATION 
TIPS 

Back Side 

Top Side 

Содержание SUPERSCAN-T

Страница 1: ...rupts the angle DESCRIPTION SPECIFICATION Power Supply 12 24 VAC VDC 10 Current Consumption Master On 60 mA max Off 30 mA max Slave On 40 mA max Off 30 mA max Inhibit Input 12 24 VAC VDC 10 inhibited when voltage is applied Monitoring Request Input 12 35 VDC required polarity sensitive Min pulse width duration 50 ms Output Interface relay Relay max contact rating is 1A 30v resistive Detection Rang...

Страница 2: ...simply pull the tab out away and downward from the extrusion then rotate the module out from extrusion image below right To re install simply reverse the procedure The PCB must first be installed into the adjustment clip then installed into the aluminum extrusion IMPORTANT NOTE The end of the extrusion that is towards the pivot end of a center hung door should be in far enough from the edge of the...

Страница 3: ...below Again be sure not to drill through any through bolts or braces within the door A The extension wire going between the terminal blocks should be approximately 18 long and can then be cut back as needed 8 Next a wire passage hole will be required in the door header image below left and also in the jamb tube image below right at approximately the same height as the SuperScan T The wire transfer...

Страница 4: ...the opposite end until all mechanical adjustments have been completed Refer to the appendices of this document for various wiring schematics Terminal Explanation of Wiring Connections 1 Test input when used as a monitored sensor positive when utilizing monitoring 2 Ground negative when utilizing monitoring Negative terminal if Input inhibition is used 3 Input inhibition All detection is ignored In...

Страница 5: ...tector will remain active thereby causing the door to stay open or to not open This fail safe operation will cause the door to be inoperative in the automatic mode since there will be a constant signal either to the safety input or to the activation input of the door control depending on which module is sensing detection If an extremely IR absorbent floor is present set J1 to Background Analysis m...

Страница 6: ...nded for use without Slave modules added to the chain and is for Master only operation The jumper is located at the Output end of the Master module Master only has jumper installed on two pins closest to center of board With jumper J4 installed as shown in the image to the right middle the Master is intended for Slave modules to be added Jumper J4 is also installed on the last Slave module in the ...

Страница 7: ... below to help determine the angling The angles may have to be altered once the units have been powered up and walk tested INACTIVE ZONE B DISTANCE FROM FLOOR SUPERSCAN T ANGLE 0º 5º 10º 15º 20º 25º 8 0 6 12 19 26 33 12 0 6 12 18 24 31 16 0 5 11 16 23 29 20 0 5 10 16 21 27 Approach Side Safety Side Hinge Side Leading Edge Side Slave module Master module Door Cord must be placed on interior of door...

Страница 8: ...d non monitoring modules in the same chain observe the following rules Non monitoring Master modules CANNOT be used with monitoring Slave modules All other combinations will work however for a system to utilize monitoring all modules must be monitoring modules PROBLEM POSSIBLE CAUSE CORECTIVE ACTION SuperScan T does not work at all No LED indications Faulty power supply Faulty connections Power su...

Страница 9: ...mpliance issue is noted The equipment should be inspected annually in accordance with the minimum inspection guidelines A safety check that includes at a minimum the items listed on the safety information label must be performed during each service call If you are not an AAADM certified inspector BEA strongly recommends you have an AAADM certified inspector perform an AAADM inspection and place a ...

Отзывы: