BEA PHOENIX EX Скачать руководство пользователя страница 4

2

1

COM

NO

 

12-24 VAC/VDC

NC

 

N.C.

N.O.

COM

R

*

R

Page 4 of 8  

75.5863.04 PHOENIX EX 20210701

RED

BLACK

WHITE

GREEN

YELLOW

Tamper Switch 

location is COM and will operate 

with N.O. or N.C. outputs. 

Maximum angle 

(+30° above horizon)

Minimum angle 

(-90° below horizon)

WIRING

MOUNTING

a)  Bolt the bracket securely to the wall or other rigid surface. 

Make sure that the two 

5

16

 - 18 Allen head bolts are loose so that the sensor can rotate freely.

b)  Rotate the sensor to the appropriate angle for the application. When the bracket rotates, it will click. Every 

click represents a 7.5° angle adjustment.

c)  Lock the angle adjustment by tightening the two 

5

16

 - 18 Allen head bolts.

Horizontal angle adjustments can be made by loosening the mounting bolts on the base and twisting to the 
desired angle.

TRANSIENT SUPPRESSION DEVICE

TO USER PANEL

SENSOR OUTPUT

Connect the wires to the controller/PCB (i.e. intrusion detection 

system). 

If necessary, an optional grounding lug is provided to ground 

the equipment to minimize the risk of electrostatic charge.  The 

equipment must be installed in such a manner that accidental 

discharge will not occur. 

The grounding lug is not required for product functionality but 

may be required for the application and/or local, national, and 

international regulations, codes, and standards.

* The Tamper Switch is N.C. with housing face plate cover 

attached. Removing the housing face plate causes the switch 

to open. System resistors may be applied at the Tamper Switch 

inside the housing or outside at a given location.

Содержание PHOENIX EX

Страница 1: ...Explosion proof housing 2 Microwave sensor 3 Grounding lug 4 Cable port NPT pipe thread 5 Adjustable bracket PHOENIX EX for normal to high mounting 11 5 23 ft PHOENIX EX XL for low mounting 6 5 11 5 ft PHOENIX EX WIDE for wide detection field 11 5 21 ft Visit website for available languages of this document DESCRIPTION ENGLISH ...

Страница 2: ...t 8 2ft PHOENIX EX WIDE 30 x 11ft 21ft typical at 30 and field size 9 Min detection speed 2 in s Supply voltage 12 24 VAC 10 12 24 VDC 30 10 Mains frequency 50 60 Hz Max power consumption 2W Output max voltage max current max power relay free of potential change over contact 42V AC DC 1A resistive 30 W DC 60 VA AC Optional end of line resistor s 1 8 Watt Temperature range 22 140 F Housing certific...

Страница 3: ...ode cycle the power For the first minute you can access the sensor without an access code SAVING AN ACCESS CODE DELETING AN ACCESS CODE DELETING AN UNKNOWN ACCESS CODE START END AN ADJUSTMENT SESSION press and hold either push button until the LED flashes or stops flashing SCROLL THROUGH PARAMETERS press the right push button CHANGE VALUE OF CHOSEN PARAMETER press the left push button RESET TO FAC...

Страница 4: ...rizontal angle adjustments can be made by loosening the mounting bolts on the base and twisting to the desired angle TRANSIENT SUPPRESSION DEVICE TO USER PANEL SENSOR OUTPUT Connect the wires to the controller PCB i e intrusion detection system If necessary an optional grounding lug is provided to ground the equipment to minimize the risk of electrostatic charge The equipment must be installed in ...

Страница 5: ...n towards sensor uni AWAY one way detection away from sensor A active output relay energizes upon detection P passive output relay de energizes upon detection PHOENIX EX Mounting height 16 ft PHOENIX EX WIDE Mounting height 11 5 ft PHOENIX EX XL Mounting height 8 ft DETECTION FIELD DIMENSIONS SETTINGS To make adjustments to the sensor press 7 0 1 2 1 1 FIELD SIZE Parameter number 2 HOLD OPEN TIME ...

Страница 6: ...of all targets pedestrians and parallel traffic are detected 1 no specific filter 2 filter against disturbances recommended in case of vibrations rain etc Detection only of vehicles moving pedestrians and parallel traffic are not detected disturbances are filtered The vehicle detection filter increases the response time of the sensor Always check if the chosen value is optimal for the application ...

Страница 7: ... and the sensor detects raindrops or vibrations Ensure detection mode is unidirectional Increase detection filter value In highly reflective environments the sensor detects objects outside of its detection field Change the antenna angle Reduce field size Increase detection filter value Vehicle detection filter is used but pedestrians are still detected Chosen value is not optimal for the given app...

Страница 8: ... national and international regulations codes and standards Once installation or service work is complete a safety inspection of the door gate shall be performed per the door gate manufacturer s recommendations and or per AAADM ANSI DASMA guidelines where applicable for best industry practices Safety inspections must be performed during each service call examples of these safety inspections can be...

Отзывы: