2
1
COM
NO
12-24 VAC/VDC
NC
N.C.
N.O.
COM
R
*
R
Page 4 of 8
75.5863.04 PHOENIX EX 20210701
RED
BLACK
WHITE
GREEN
YELLOW
*
Tamper Switch
location is COM and will operate
with N.O. or N.C. outputs.
Maximum angle
(+30° above horizon)
Minimum angle
(-90° below horizon)
WIRING
MOUNTING
a) Bolt the bracket securely to the wall or other rigid surface.
Make sure that the two
5
⁄
16
- 18 Allen head bolts are loose so that the sensor can rotate freely.
b) Rotate the sensor to the appropriate angle for the application. When the bracket rotates, it will click. Every
click represents a 7.5° angle adjustment.
c) Lock the angle adjustment by tightening the two
5
⁄
16
- 18 Allen head bolts.
Horizontal angle adjustments can be made by loosening the mounting bolts on the base and twisting to the
desired angle.
TRANSIENT SUPPRESSION DEVICE
TO USER PANEL
SENSOR OUTPUT
Connect the wires to the controller/PCB (i.e. intrusion detection
system).
If necessary, an optional grounding lug is provided to ground
the equipment to minimize the risk of electrostatic charge. The
equipment must be installed in such a manner that accidental
discharge will not occur.
The grounding lug is not required for product functionality but
may be required for the application and/or local, national, and
international regulations, codes, and standards.
* The Tamper Switch is N.C. with housing face plate cover
attached. Removing the housing face plate causes the switch
to open. System resistors may be applied at the Tamper Switch
inside the housing or outside at a given location.