BEA MS21H Скачать руководство пользователя страница 3

2

3

 

75.5737.10 MS-21H 20150617 

     Page 

of 

 

WIRING

SETTINGS & ADJUSTMENTS

A - SENSING ZONE - potentiometer

COUNTERCLOCKWISE - decrease (0’’ minimum)

CLOCKWISE - increase (4’’ maximum *)

B - AUDIBLE ALERT - DIP switch 1 (left)

ON - audible alert pulsed for 0.5 seconds during detection

OFF - audible alert off

C - LED - DIP switch 2 (right)

ON - LED on at rest, pulsed off for 0.5 seconds during detection

OFF - LED off at rest, pulsed on for 0.5 seconds during detection

* Maximum sensing zone will vary depending on size (area), orientation, and 

speed of object as well as environmental conditions.

IMPORTANT WIRING NOTES

:

Be sure to always use the BEA provided isolation module. *

If using a shielded wire harness, both ends of the shielding foil must be connected to Earth Ground.

If using a wire harness with more than 5 conductors, all extra conductors must be wired to Earth Ground.

A

B C

* It is required that each MS21 be powered by a separate isolation module

NOTE:  It will take approximately 10 seconds to complete the initilization sequence once powered.

DOOR HEADER

GREEN
YELLOW
GREEN / YELLOW

RED
BLACK
WHITE

RED

BLACK

WHITE

GREEN

BLUE

Installer Provided 

Wire Harness

ISOLATION 

MODULE

RED

BLACK

WHITE

GREEN

BLUE

WIRE NUT

NO

COM

− POWER

+ POWER

NC

EARTH GROUND

Isolation Module

Signal

Harness Wire

Isolation Module Wire

Door Control Terminal

To Door Control

(6 wire side)

AC/DC +

-

Red

AC/DC +

AC/DC -

-

Black

AC/DC -

COM

-

White

ACT COM

NO

-

Green

ACT NO

NC

-

Yellow

ACT NC

Earth Ground

-

Green / Yellow

Earth Ground

To MS21

(5 wire side)

COM

White

White

-

NO

Green

Green

-

AC/DC

Red

Red

-

AC/DC

Black

Black

-

Earth Ground

Blue

Blue

-

Wire nut harness wires and isolation module wires together and connect isolation module wires to the door control, according to the chart below.

NOTE:  From isolation module to ACT, use 
either green (NO) OR yellow (NC)

Содержание MS21H

Страница 1: ...arness 3 set screws 7 DIP switches 4 backplate 8 potentiometer Sensing Zone is dependent upon Size area of object Orientation of object Speed of object Environmental conditions 5 conduct wire needed between sensor and door control Technology Capacitive Sensing Detection Mode Proximity Supply Voltage 12 24 VAC DC Current Consumption 37 mA typical Temperature Range 20 F to 120 F Enclosure Rating NEM...

Страница 2: ...0 Complete Section 2 WIRING and Section 3 SETTINGS ADJUSTMENTS prior to continuing installation in Section 4 Only trained and qualified personnel may install and setup the sensor The warranty is invalid if unauthorized repairs are made or attempted by unauthorized personnel Always test the proper operation of the installation before leaving the premises The door control unit and the door cover pro...

Страница 3: ...ors all extra conductors must be wired to Earth Ground A B C It is required that each MS21 be powered by a separate isolation module NOTE It will take approximately 10 seconds to complete the initilization sequence once powered DOOR HEADER GREEN YELLOW GREEN YELLOW RED BLACK WHITE RED BLACK WHITE GREEN BLUE Installer Provided Wire Harness ISOLATION MODULE RED BLACK WHITE GREEN BLUE WIRE NUT NO COM...

Страница 4: ...remains within sensing zone for more than 5 seconds a new capacitive zone will be learned and normal operation will resume i e chewing gum stuck to faceplate Upon completion of the installation or service work at a minimum perform a daily safety check in accordance with the minimum inspection guidelines provided by AAADM Provide each equipment owner with an owner s manual that includes a daily saf...

Отзывы: