BEA MS21H Скачать руководство пользователя страница 2

1

1

PRECAUTIONS

 Page 

of 

      75.5737.10 

MS-21H 

20150617

INSTALLATION

TI

PS

AP

PLI

C

A

TI

O

N

S

NOTE:  Do not install the sensor within the swingpath of the door.

1)  Install electrical box

2)  Remove two (2) set screws

3)  Disassemble (slide up, pull out) faceplate assembly from mounting ring

4)  Temporarily mount mounting ring to electrical box

NOTE:  Observe “THIS END UP”

5)  Mark four (4) mounting ring mounting hole locations

6)  Remove mounting ring from electrical box

7)  Install four (4) wall anchors

8)  Mount (hand tighten) mounting ring to both electrical box and wall

9)  Remove back of NEMA 4 enclosure

10)  Complete Section 2 (WIRING) and Section 3 (SETTINGS & ADJUSTMENTS) prior to continuing installation in 

Section 4

Only trained and 

qualified personnel 

may install and setup 

the sensor. 

The warranty is invalid if 

unauthorized repairs are 

made or attempted by 

unauthorized personnel. 

Always test the proper 

operation of the 

installation before 

leaving the premises.

The door control unit 

and the door cover 

profile must be correctly 

grounded.

single or double gang 
electrical box may be 
used (non-metallic 
ideal)

single gang electrical 
box recommended for 
4.75’’ square version

set screws are 4/40 x 
1/2’’ Allen head screws, 
adjusted with 3/32 Allen 
wrench (supplied)

mounting screws are 
#6-32 x 1/2’’ Phillips 
head screws

Single Swing Doors

Dual Egress Swing Doors

Sim Pair Swing Doors

Sliding Doors

Содержание MS21H

Страница 1: ...arness 3 set screws 7 DIP switches 4 backplate 8 potentiometer Sensing Zone is dependent upon Size area of object Orientation of object Speed of object Environmental conditions 5 conduct wire needed between sensor and door control Technology Capacitive Sensing Detection Mode Proximity Supply Voltage 12 24 VAC DC Current Consumption 37 mA typical Temperature Range 20 F to 120 F Enclosure Rating NEM...

Страница 2: ...0 Complete Section 2 WIRING and Section 3 SETTINGS ADJUSTMENTS prior to continuing installation in Section 4 Only trained and qualified personnel may install and setup the sensor The warranty is invalid if unauthorized repairs are made or attempted by unauthorized personnel Always test the proper operation of the installation before leaving the premises The door control unit and the door cover pro...

Страница 3: ...ors all extra conductors must be wired to Earth Ground A B C It is required that each MS21 be powered by a separate isolation module NOTE It will take approximately 10 seconds to complete the initilization sequence once powered DOOR HEADER GREEN YELLOW GREEN YELLOW RED BLACK WHITE RED BLACK WHITE GREEN BLUE Installer Provided Wire Harness ISOLATION MODULE RED BLACK WHITE GREEN BLUE WIRE NUT NO COM...

Страница 4: ...remains within sensing zone for more than 5 seconds a new capacitive zone will be learned and normal operation will resume i e chewing gum stuck to faceplate Upon completion of the installation or service work at a minimum perform a daily safety check in accordance with the minimum inspection guidelines provided by AAADM Provide each equipment owner with an owner s manual that includes a daily saf...