background image

3

2

WIRING (continued)

 

75.5821.00 MS08 RETROFIT 20141030 

     Page 

of 

 

SETTINGS & ADJUSTMENTS

4”

24”

MS08

Sensing Filed

Potentiometer

Output Mode Switch 

24”

4”

Toggle Mode

Pulse Mode

DETECTION ZONE - potentiometer

COUNTERCLOCKWISE - decrease (4’’ minimum)

CLOCKWISE - increase (24’’ maximum *)

OUTPUT MODE - slide switch

PULSE - switch down

TOGGLE - switch up

* Maximum Detection Zone will 

vary depending on size (area), 

orientation, and speed of object as 

well as environmental conditions.

SENSOR FUNCTIONALITY

TIMED MODE - Recommended for automatic door applications.  In Timed Mode, a detection 
activates the relay and the relay holds for a predetermined amount of time adjusted by the Output 
Time potentiometer (1 to 30 seconds, counterclockwise - decrease, clockwise -increase).

TOGGLE MODE - Recommended for switch applications.  In Toggle Mode, a detection activates the 
relay and a second detection deactivates the relay.  The relay will hold indefinitely until a second 
detection occurs.

For the 900 MHz wireless programming instructions, please reference BEA User’s Guide 75.5786 
which comes with the 900 MHz wireless receiver (sold separately).

WIRELESS FUNCTIONALITY

The 900 MHz wireless transmitter (10TD900PB) comes prewired to the MS08 sensor’s NO (green) 
and COM (white) terminals.  The 900 MHz wireless transmitter is powered externally by two (2) AAA 
batteries. 

For the 900 MHz wireless programming instructions, please reference BEA User’s Guide 75.5786 
which comes with the 900 MHz wireless receiver (sold separately).

WIRELESS

Содержание MS08 RETROFIT

Страница 1: ... 60 Hz 12 24 VDC 30 10 Current Consumption 1 5 W Output Relay contact rating max voltage Relay contact rating max current Max switching power Relay with switch over contact voltage free 60 VDC 125 VAC 1 A resistive 30 W DC 60 VA AC Detection Range 4 24 inches adjustable Output Hold Time 0 5 s in pulse mode Temperature Range 4 F to 131 F Material ASA Nylon PC Certification Electromagnetic compatibi...

Страница 2: ...lectrical box may be used non metallic ideal plastic ring adapter may be used to install double gang faceplate onto various mounting boxes weather resistent foam gasket may be used to protect against weather M S 0 8 PWR Black 12 to 24 VAC VDC 5 to 10 PWR Red 12 to 24 VAC VDC 5 to 10 NC Empty NC Contact NO Green NO Contact COM White Common at Door Control C O N T R O L Black 12 to 24 VAC VDC Red 12...

Страница 3: ...sted by the Output Time potentiometer 1 to 30 seconds counterclockwise decrease clockwise increase TOGGLE MODE Recommended for switch applications In Toggle Mode a detection activates the relay and a second detection deactivates the relay The relay will hold indefinitely until a second detection occurs For the 900 MHz wireless programming instructions please reference BEA User s Guide 75 5786 whic...

Страница 4: ...port 1 800 407 4545 Customer Service 1 800 523 2462 General Tech Questions Tech_Services beainc com Tech Docs www beasensors com FCC FCC G9B 21019 This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesi...

Отзывы: