2
WIRING
1
PRECAUTIONS
Only trained and
qualified personnel
may install and setup
the sensor.
The warranty is invalid if
unauthorized repairs are
made or attempted by
unauthorized personnel.
Always test the proper
operation of the
installation before
leaving the premises.
The door control unit
and the door cover
profile must be correctly
grounded.
1
INSTALLATION
TI
PS
AP
PLI
C
A
TI
O
N
S
Single Swing Doors
Dual Egress Swing Doors
Sim Pair Swing Doors
Sliding Doors
NOTE: Do not install the sensor within the swingpath of the door.
Page
2
of
4
75.5821.00
MS08
RETROFIT
20141030
single or double gang
electrical box may be
used (non-metallic
ideal)
plastic ring adapter may
be used to install double
gang faceplate onto
various mounting boxes
weather resistent foam
gasket may be used to
protect against weather
M
S
0
8
• PWR
: Black - 12 to 24 VAC / VDC: -5% to +10%
• PWR
: Red - 12 to 24 VAC / VDC: -5% to +10%
•
NC
: Empty - NC Contact
• NO
: Green - NO Contact
• COM
: White - Common at Door Control
C
O
N
T
R
O
L
Black - 12 to 24 V
AC / VDC
Red - 12 to 24 V
AC / VDC
White - Com at Door Control
Green - NO Contact
Empty - NC Contact
Connect the exiting 2 wires running through the wall (previously used for the activation relay of the
hardwired, mechanical pushplate) to the MS08 sensor’s PWR (black) and PWR (red) terminals. At
the door control, move the 2 wires from the activation circuit to power (see Technical Specifications
for power information).
SENSOR