To delete the virtual "Pull-Cord" zone, simply relaunch a "Pull-Cord" teach-in without standing in the
scanning zone. After 1 minute, the sensor flashes 5x orange. Push LOCK (
)to exit the
adjustment mode.
1. Launch a "Pull-Cord" teach-in by remote control. You can create up to three different pull-cords.
2. Go to the position where you want to activate the door by a virtual pull-cord. Do not move.
3. The learning process starts. The sensor confirms that a person has been seen. Do not move untill the LED stops
flashing!
If the sensor flashes orange, see TROUBLESHOOTING.
When two people are standing in the field, the pull-cord will be created closest to the sensor.
4. The teach-in ends successfully. If not, refer to the TROUBLESHOOTING section on page 15.
NOTE: You can choose an object type and its minimum presence time using the remote control - see page 10.
TEACH-IN: PULL-CORD
The heating function is also available via LCD. This cannot be accessed/programmed via remote control.
See the menu path below to access heating values:
MAIN
QUICK START
>MORE
OFF (default)
ECO
AUTO