background image

75.5916.03 LZR-WIDESCAN 20180821   

Page 1 of 16

75.5916.03 LZR-WIDESCAN 20180821   

Page 1 of 16

75.5916.03 LZR-WIDESCAN 20180821   

Page 1 of 16

75.5916.03 LZR-WIDESCAN 20180821   

Page 1 of 16

EN

MOTION, PRESENCE, AND SAFETY SENSOR 

FOR INDUSTRIAL DOORS

(US VERSION)

Содержание LZR-WIDESCAN

Страница 1: ... Page 1 of 16 75 5916 03 LZR WIDESCAN 20180821 Page 1 of 16 LZR WIDESCAN 75 5916 03 LZR WIDESCAN 20180821 Page 1 of 16 75 5916 03 LZR WIDESCAN 20180821 Page 1 of 16 EN MOTION PRESENCE AND SAFETY SENSOR FOR INDUSTRIAL DOORS US VERSION ...

Страница 2: ... 5916 03 LZR WIDESCAN 20180821 Page 2 of 16 75 5916 03 LZR WIDESCAN 20180821 1 main connector 2 protection film 3 laser window 4 USB cap 5 LED display 6 cover 7 cover lock 8 cable passage 9 LCD screen 10 keypad 11 tilt angle adjustment screw 1 12 parallel angle adjustment screw 2 13 lateral angle lock screw 1 14 mounting bracket DESCRIPTION ...

Страница 3: ...void moving objects and light sources in the detection field Avoid exposure to sudden and extreme temperature changes Avoid direct exposure to high pressure cleaning Avoid extreme vibrations Do not cover the sensor Do not look directly into the laser emitter or the visible red laser beams CAUTION Use of controls adjustments or performance of procedures other than those specified herein may result ...

Страница 4: ...t width depth direction and speed SENSOR DETECTS IF motion in motion field certain object type certain direction SENSOR DETECTS IF presence in presence field certain object type SENSOR DETECTS IF presence in safety field PRESENCE SAFETY There are 4 additional opening functions All detection functions can be combined to trigger a specific output Motion detection of other moving object type in motio...

Страница 5: ...ning the angle lock screw Lock the cover by turning the lock screw clockwise Pull the two legs on top in order to open the cover Factory value User s Guide Presence Motion Pull Cord Speed Height Safety Motion Factory value LCD Important Good to know Main functions Additional opening functions OPENING THE SENSOR LED SIGNALS SYMBOLS CLOSING THE SENSOR LED flashing LED flashing slowly LED off LED fla...

Страница 6: ...ion the sensor horizontally as shown and secure the sensor to the mounting bracket Plug in the connector and pass the cable PN 20 5399 through the cable passage without making a loop Connect the wires accordingly The output functions can be configured if necessary see page 10 Mounting height as high as possible max 19 6 The size of the detection field depends on the mounting height Mounting positi...

Страница 7: ...ening the angle lock screw see page 4 Make sure the curtain is parallel to the door by adjusting one or both screws on the side PARALLEL ANGLE TILT ANGLE Launch the POSITION WIZARD to position the detection field correctly in front of the door 1 Push and hold OK to launch the POSITION WIZARD 2 Rotate the sensor in order to align the center of the red spots with the center of the door Push OK 3 Rot...

Страница 8: ... enter an access code from 1 to 4 digits If you do not know the access code cycle power If necessary select the corresponding detection field before selecting the parameter and changing the value The second LED indicates the detection field MOTION PULL CORD PRESENCE SAFETY Return to previous menu or display Select your Language before entering the first LCD menu Within the first 30 seconds of powe...

Страница 9: ...ax depth 1 3 max presence time 10 min uncovered zone 5 3 4 interior confined space traffic from and to all directions no storage near door width max depth max object type vehicle direction uni width max depth 6 6 object type vehicle max presence time 30 min width max depth 1 3 max presence time 10 min uncovered zone 5 3 4 interior or exterior no parallel traffic storage on one side of door STANDAR...

Страница 10: ...e reset of all values partial reset of all values except IN OUT The service mode deactivates the presence and safety detection during 15 minutes and can be useful during an installation a mechanical teach in of the door or maintenance work Exit the service mode by using the same sequence Pressing magic wand twice activates the 2 laser spots enabling angle adjustments and sensor positioning standar...

Страница 11: ... Relay Function Relay Logic Relay Holdtime motion motion or pull cord presence safety pull cord motion speed motion height motion pull cord safety motion pull cord presence motion motion or pull cord presence safety pull cord motion speed presence height motion pull cord safety motion pull cord presence motion motion or pull cord presence NO NO passive 100 ms 100 ms 100 ms NC NC active safety pull...

Страница 12: ...ou want to activate the door by a virtual pull cord Do not move 3 The learning process starts The sensor confirms that a person has been seen Do not move untill the LED stops flashing If the sensor flashes orange see TROUBLESHOOTING When two people are standing in the field the pull cord will be created closest to the sensor 4 The teach in ends successfully If not refer to the TROUBLESHOOTING sect...

Страница 13: ... 78 7 88 6 98 4 108 3 118 1 127 9 137 3 157 5 factory default is bold underlined NOTE Each of these available parameters is higher than XX inches I e If the parameter 108 4 is chosen the sensor will detect objects with a MINIMUM height of 108 4 inches The door opens partially motion detection lower than 7 6 The door opens completely presence detection higher than 7 6 HEIGHT TRIGGER By default all ...

Страница 14: ...p 4 Make sure the field is larger than desired The existing field size can be reduced and adapted but cannot exceed the configured size Step away from the detection field and remove any objects ladder tools etc Go to the starting position of your detection field see 1st picture below The delay after which the teach in is launched is 60 seconds by LCD adjustable to 30 or 120 sec via Quick Start Mor...

Страница 15: ...lateral angle Adjust lateral angle max 45 Diagnostics LCD Launch install teach in E5 HEIGHT Faulty teach in due to mounting height Adjust mounting height max 19 6 min 6 6 Launch install teach in E5 TIME OUT Faulty teach in Relaunch install teach in Make sure that there is no motion detection during at least 5 seconds when LED starts flashing red green Slightly change your position and relaunch an ...

Страница 16: ...l Color PC ASA Black Rotation angles on bracket 45 to the right 15 to the left lockable Tilt angles on bracket 10 5 Protection degree NEMA 4 IP65 Temperature range 22 140 F Vibrations 2 G Norm conformity EN 61000 6 2 EN 61000 6 3 EN 60950 1 EN 60825 1 EN ISO 13849 1 Pl d CAT2 EN 62061 SIL 2 EN 61496 1 ESPE Type 2 EN 12978 EN 50581 Specifications are subject to change without prior notice All value...

Отзывы: