75.5792.05 LZR-S600 20180814
Page 7 of 12
3
4
C1
C3C4
C2
a
b
c
75.5792.05 LZR-S600 20180814
Page 7 of 12
POSITIONING
Adjust the
lateral position
of
the detection field.
Adjust the
tilt angle
of the
detection field with the 3 mm
hex key.
Lock the position
of the
mounting bracket to avoid
malfunctioning in case of
extreme vibrations.
Unlock the sensor and activate the visible laser beams.
The visible laser beams indicate the approximate
postion of curtain C1 and the angle of
the detection field.
The visible laser beams will remain active for
15 minutes or can be turned off the same way
they were activated.
MOUNTING SIDE
Select the corresponding mounting side.
The sensor learns its environment and automatically
determines the detection field(s). Both red LEDs flash slowly and
the 3 visible laser beams automatically light up for 30 seconds.
WITH BACKGROUND
WITHOUT BACKGROUND
The sensor memorizes the floor as
reference point and signals a fault
when its orientation is changed
(observe orange flashing LED).
No reference point is memorized.
No alarm in case of interference.
Stay outside of the detection field to avoid disturbances.
left
right
left
right
center