75.5792.05 LZR-S600 20180814
Page 1 of 12
LZR
®
-s600
LASER SCANNER FOR BUILDING AUTOMATION & SECURITY
with max. detection range of 82 ft x 82 ft
User’s Guide
EN
Страница 1: ...75 5792 05 LZR S600 20180814 Page 1 of 12 LZR s600 75 5792 05 LZR S600 20180814 Page 1 of 12 LASER SCANNER FOR BUILDING AUTOMATION SECURITY with max detection range of 82 ft x 82 ft User s Guide EN ...
Страница 2: ...AINTENANCE Do not look into the laser emitter or the visible red laser beams The warranty is void if unauthorized repairs are made or attempted by unauthorized personnel Only trained and qualified personnel are recommended to install and set up the sensor Test the proper operation of the installation before leaving the premises Avoid moving objects and light sources in the detection field Avoid co...
Страница 3: ...et 10 cable conduits 4 SYMBOLS Caution Laser radiation Remote control sequence Factory values Possible remote control adjustments Alarm LED SIGNAL Tip Quick installation DETECTION LEDs no detection green ERROR LED POWER LED detection red no error off error orange no power on power blue 1 Detection LED relay 1 opening field 2 Detection LED relay 2 safety field 3 Error LED 4 Power LED All 4 LEDs can...
Страница 4: ...d red red off red red red off ADJUSTING ONE OR MORE PARAMETERS CHECKING A VALUE RESTORING TO FACTORY VALUES The access code is recommended for sensors installed close to each other SAVING AN ACCESS CODE Enter the existing code DELETING AN ACCESS CODE 30 minutes after last use the sensor locks access to the remote control session To regain access cycle the power The remote control session will then...
Страница 5: ...NING Field 2 only curtain C1 active triggers relay 2 ALARM Adapt the field widths ex 20 ft Reduce field 2 to one curtain C1 20 ft 20 ft DAY AND NIGHT FEATURE During night time field 2 is active as well and triggers relay 2 intrusion alarm Adapt the field width of field 1 ex 20 ft During day time only field 1 is active and triggers relay 1 Adapt the field width of field 2 ex 25 ft 20 ft 25 ft ...
Страница 6: ...on the bracket Close and secure the protection cover NOTE FACTORY WARRANTY VOIDED IF PROTECTION COVER IS NOT USED Open the protection cover plug the connector and position the cable in the slit Use the visual aid below to ensure correct wiring to the door control CONNECTOR side view BLACK CONNECTOR RED BLUE WHITE BLUE WHITE GREEN ORANGE WHITE BLACK ORANGE BLACK GREEN WHITE WIRE COLORS FUNCTION Pow...
Страница 7: ... detection field The visible laser beams will remain active for 15 minutes or can be turned off the same way they were activated MOUNTING SIDE Select the corresponding mounting side The sensor learns its environment and automatically determines the detection field s Both red LEDs flash slowly and the 3 visible laser beams automatically light up for 30 seconds WITH BACKGROUND WITHOUT BACKGROUND The...
Страница 8: ...EARN The Learn can be launched either via remote control or by connecting the orange and orange black wires Launch a Learn under the following conditions after changing the sensor position when new objects are added to or changed in the detection zone During Learn the sensor learns its surroundings and adapts the detection zone shape Objects in the detection field will be cut out To launch a Learn...
Страница 9: ... mounting height Example At 10 feet the distance between C1 and C4 is 1 5 feet Ex C1 C2 are active on safety field C3 C4 are active on optional field C1 is active on both fields C2 C3 are active on safety field C4 is inactive All curtains are active on both fields C1 C2 C3 C4 OUTPUT CONFIGURATION R1R2 R relay output IMMUNITY FILTER MIN OBJECT SIZE approximate values OUTPUT ACTIVATION DELAY The out...
Страница 10: ...ng side setting If no reference point is found set the mounting side to value 3 to 5 Launch a new Learn Sensor is masked Verify and clean the front screens with a damp cloth Orange LED is on Both detection LEDs are orange Power supply voltage exceeds acceptable limits Check power supply voltage Sensor exceeds temperature limits Verify the temperature of the environment Protect the sensor from sunl...
Страница 11: ...c relays galvanic isolated polarity free 35 VDC 24 VAC 80 mA resistive tON 5 ms tOFF 5 ms typ 30 Ω 0 7 V 20 mA 10 µA Input Max contact voltage Voltage threshold 2 optocouplers galvanic isolated polarity free 30 VDC over voltage protected Log H 8 VDC Log L 3 VDC Response time monitoring input 5 ms LED signal 1 blue LED power on status 1 orange LED error status 2 bi colored LEDs detection output sta...
Страница 12: ...u détecteur de l appareil par conséquent BEA ne garantit aucun usage du capteur en dehors de son but prévu BEA recommande fortement que les techniciens d installation et de services soient certifiés AAADM pour les portes piétonnières certifiés IDA pour les portes portails et formés en usine pour le type de système de portes portails Les installateurs et le personnel de service sont responsables d ...