background image

Page 12 of 12 

 

75.5667.10 LZR-I30 20161212

Page 12 of 12 

 

75.5667.10 LZR-I30 20161212

Tech Support: 1-800-407-4545 | Customer Service: 1-800-523-2462 | General Tech Questions: [email protected] | Tech Docs: www.beasensors.com

©

BE

A

 

 | 

O

rig

in

al

 in

str

uc

ti

on

s

 |

 

75

.5

66

7

BEA hereby declares that the LZR

®

-I100/-I110 is in conformity with the basic requirements and the other relevant provisions of 

the directives 2006/95/EC, 2002/95/EC, 2004/108/EC and 2006/42/EC.
Notified Body for EC inspection: 0044 - TÜV NORD CERT GmbH, Langemarckstr. 20, 45141 D-Essen
EC-type examination certificate number: 44 205 11 392410-002
Angleur, May 2011 

Jean-Pierre Valkenberg, Authorized representative and responsible for technical documentation

The complete declaration of conformity is available on our website:  www.bea-industrial.be

For EC countries: according to the directive 2012/19/EU for Waste Electrical and Electronic Equipment (WEEE)

PL

EA

SE K

EE

P F

O

R F

U

RT

H

ER U

SE

D

ES

IG

N

ED

 FO

R C

O

LO

R P

RI

N

TI

N

G

Содержание LZR-I30

Страница 1: ...75 5667 10 LZR I30 20161212 Page 1 of 12 LZR I30 75 5667 10 LZR I30 20161212 Page 1 of 12 EN max detection range of 30 ft x 30 ft LASER SCANNERS FOR INDUSTRIAL DOORS ...

Страница 2: ...sensor The installer of the door system is responsible for carrying out a risk assessment and installing the sensor and the door system in compliance with applicable national and international regulations and standards on door safety and if applicable the machinery directive 2006 42 EC Other use of the device is outside the permitted purpose and can not be guaranteed by the manufacturer The manufa...

Страница 3: ...eption 3 LED signals 4 4 screws for position lock 2 5 connector 6 protection cover 7 visible laser beams 3 8 notches for tilt angle adjustment 2 9 adjustable bracket 10 cable conduits 4 1 Detection LED relay 1 optional field 2 Detection LED relay 2 safety field 3 Error LED 4 Power LED Remote control sequence Possible remote control adjustments Factory values According to Not according to LED flash...

Страница 4: ...AMETERS CHECKING A VALUE RESTORING TO FACTORY VALUES SAVING AN ACCESS CODE DELETING AN ACCESS CODE The access code is recommended for sensors installed close to each other After unlocking the red LED flashes and the sensor can be adjusted by remote control If the red LED flashes quickly after unlocking you need to enter an access code from 1 to 4 digits field width 13 7 ft field width is defined b...

Страница 5: ... an opening is not possible use the cable conduits on the back side of the bracket Position the bracket and fasten the 4 screws firmly in order to avoid vibrations Position the housing on the bracket and turn the sensor until the two triangles are face to face MOUNTING WIRING POWER SUPPLY RELAY 1 OPTIONAL FIELD RELAY 2 SAFETY FIELD TEST NOT USED RED BLACK WHITE GREEN WHITE BLACK GREEN WHITE BLUE B...

Страница 6: ...ion Unlock the sensor and activate the visible laser beams in order to position the curtains parallell to the door POSITIONING The distance between the inner curtains of the 2 sensors shall not exceed 8 in to ensure safety according to EN ISO 13849 1 2008 CAT 2 Pl d After setting the mounting side the safety and the optional field have the same dimensions The visible laser beams stay activated for...

Страница 7: ...ing teach in the sensor learns and adapts its detection field shape according to its surroundings During teach in the sensor learns its surroundings and adapts the detection field shape to these Objects in the detection field will be cut out WIDTH HEIGHT no field Ex for a field width of 62 in FIELD DIMENSIONS SAFETY FIELD TEACH IN After the teach in the field dimensions can be changed by the remot...

Страница 8: ...r wait until the LED switches to green Launch a new VPB teach in each time the sensor position is changed or new objects are added to or changed in the detection zone ATTENTION This VPB teach in is different from the safety field teach in 3 s In order to configure the field dimensions you have to cancel the virtual push button function by launching a new VPB teach in without any movement in the de...

Страница 9: ...ght and side When mounted on the left the distance between curtain C1 and curtain C4 is approximately 4 in for every 3 25 ft mounting height Example at 200 in the distance between C1 and C4 is 20 in OUTPUT ACTIVATION DELAY approximate values off Ex C1 C2 are active on safety field C3 C4 are active on optional field C1 is active on both fields C2 C3 are active on safety field C4 is inactive CURTAIN...

Страница 10: ...e and connexion Check wiring The BLUE and BLUE WHITE cable have to be connected to the test input or the power supply Check the size of the fields Launch a teach in Step out of the field and or remove the any object s from the field and launch a teach in Activate the 3 red beams and check if the position of the sensor is correct If not adjust the hex screws Verify the field size Launch a teach in ...

Страница 11: ...3516 0 8 in 118 in 1 4 in 197 in 2 75 in 30 ft 700 mm x 300 mm x 200 mm testbody A according to EN 12445 wavelength 905 nm max output pulse power 75 W CLASS 1 wavelength 650 nm max output CW power 3 mW CLASS 3R 10 35 V DC sensor side to be operated from SELV compatible power supplies only 5 W 1 8 A max 80 ms 35 V 33 ft typ 20 ms max 80 ms output activation delay 2 electronic relays galvanic isolat...

Страница 12: ...s of the directives 2006 95 EC 2002 95 EC 2004 108 EC and 2006 42 EC Notified Body for EC inspection 0044 TÜV NORD CERT GmbH Langemarckstr 20 45141 D Essen EC type examination certificate number 44 205 11 392410 002 Angleur May 2011 Jean Pierre Valkenberg Authorized representative and responsible for technical documentation The complete declaration of conformity is available on our website www bea...

Отзывы: