Page 16 of 16
75.5984.01 LZR-H100 20181221
Page 16 of 16
75.5984.01 LZR-H100 20181221
Technology
LASER scanner, time-of-flight measurement (4 laser curtains)
Detection mode
motion and presence
Max. detection field
32’ × 32’
Remission factor
>2%
Angular resolution
0.3516°
Emission characteristics
IR laser:
Red visible laser:
wavelength 905 nm; max. output pulse power 75 W (CLASS 1)
wavelength 650 nm; max. output CW power 3 mW (CLASS 3R)
Supply voltage
10 – 35 VDC @ sensor side
Power consumption
<5 W
Peak current at power-on:
1.8 A (max. 80 ms @ 35 V)
Cable length:
33’
Response time
Motion detection:
Presence detection:
typ. 200 ms (adjustable)
typ. 20 ms (max. 80 ms)
Output:
Max. switching voltage:
Max. switching current:
Switching time:
Output resistance:
Voltage drop on output:
Leakage current:
2 electronic relays (galvanic isolated – polarity free)
35 VDC / 24 VAC
80 mA (resistive)
t
ON
=5 ms; t
OFF
=5 ms
typ 30 Ω
<0.7 V @ 20 mA
<10 µA
Test input:
Max. contact voltage:
Voltage threshold:
1 optocoupler (galvanic isolated - polarity free)
30 VDC (over-voltage protected)
Log. H: >8 VDC
Log. L: <3 VDC
LED-signal:
1 blue LED: power-on status
1 orange LED: error status
2 bi-colored LEDs: detection/output status (green = no detection, red = detection)
Dimensions:
3
5
⁄
8
”× 2
3
⁄
4
”× 5”(W × H × D) mounting bracket: +
1
⁄
2
”
Material / Colour:
PC/ASA, black
Mounting angles on bracket:
-45°, 0°, 45°
Rotation angles on bracket:
-5 – 5° (lockable)
Tilt angles on bracket:
-3 – 3°
Protection degree:
IP65
Temperature range:
powered: -22 – 140 °F unpowered: 14 – 140 °F
Humidity:
0 – 95% non-condensing
Vibrations:
<2 G
Pollution on front screens:
max. 30%; homogenous
Norm conformity:
IEC 61000-6-2; IEC 61000-6-3; IEC 60950-1; IEC 60825-1
ISO 13849-1 (Pl “d” CAT 2); IEC 62061 (SIL 2); IEC 61496-1 (Type 2)
TECHNICAL SPECIFICATIONS
BEA, the sensor manufacturer, cannot be held responsible for incorrect installations or inappropriate adjustments of the sensor/device; therefore, BEA
does not guarantee any use of the sensor outside of its intended purpose.
BEA strongly recommends that installation and service technicians be AAADM-certifi ed for pedestrian doors, IDA-certifi ed for doors/gates, and factory-
trained for the type of door/gate system.
Installers and service personnel are responsible for executing a risk assessment following each installation/service performed, ensuring that the sensor
system installation is compliant with local, national, and international regulations, codes, and standards.
Once installation or service work is complete, a safety inspection of the door/gate shall be performed per the door/gate manufacturer recommendations
and/or per AAADM/ANSI/DASMA guidelines (where applicable) for best industry practices. Safety inspections must be performed during each service
call – examples of these safety inspections can be found on an AAADM safety information label (e.g. ANSI/DASMA 102, ANSI/DASMA 107).
Verify that all appropriate industry signage and warning labels are in place.
BEA INSTALLATION/SERVICE COMPLIANCE EXPECTATIONS
PLEASE KEEP FOR FUR
THER USE – DESIGNED FOR COLOR PRINTING
Tech Support: 1-800-407-4545 | Customer Service: 1-800-523-2462
General Tech Questions: [email protected] | Tech Docs: www.BEAinc.com
©BEA
| Original Instructions |
75.5984.01 LZR-H100 20181221
Specifications are subject to change without prior notice.
All values measured in specific conditions.