FACTORY VALUES
9
DETECTION
FIELD
REDIRECTION
R1
R2
field 2
field 1
error
alarm
field 1 or
field 2
field 1
field 2
error
alarm
field 1 or
field 2
DETECTION
MODE
LED
ACTIVATION
LED OFF
LED ON
OUTPUT
CONFIGURATION
R1
NC
NC
NO
NO
NO
NC
NO = normally open
NC = normally closed
NO
NC
NO NC
NO POWER
NO DETECTION
DETECTION
*R2
* R2 R2 default connection: Pink/ Grey
ANTIMASKING &
BACKGROUND
Antimasking: when laser window is covered, the scanner will go into error mode. Back-
ground: when background is changed, the scanner will go into error mode.
antimasking
ON
OFF
ON
ON
OFF
OFF
OFF
ON
background
50
200
300
400
500
ms
100
20
80
OUTPUT
TERMINATION
DELAY
Output termination delay:
After the detection signal disappears, the output will
remain the set duration, then switch off.
HD MODE
HS MODE
HD
:
HS
:
High resolution mode
High speed mode
Please lauch a new teach-in with every adjustment.