SET-UP 
INSTRUCTIONS

 

DIPSWITCH 
SETTINGS

 

 
 
WITHOUT SAFETY BEAMS:

 

The new LO-21K provides communication through data lines to the BODYGUARD / DK-12 to inhibit the 
BODYGUARD / DK-12 in the closing cycle of the door, therefore the GREEN & BLUE wires of the LO-21K no longer 
have to be connected to the BODYGUARD / DK-12.  If the GREEN & BLUE wires are connected, no damage to the 
unit will result.   
 

 
WITH SAFETY BEAMS:

 

When safety beams are installed, the LO-21K provides the safety signal to the door control when the beams have 
been blocked.  Therefore, the GREEN & BLUE wires of the LO-21K must be wired in parallel with the BODYGUARD 
/ DK-12 connection to the safety and common of the door control.

   

 

 
 
 
Upon powering the LO-21K , make sure that the red light on the front of the LO-21K comes on when the door is in its 
closing cycle.  If it does not come on, reverse the black and red wires from the LO-21K to the motor input for DC 
units.  If the unit is AC, ensure that the AC power is being switched on and off at the point of connection for the red 
and black wires.  Also, if using safety beams, ensure that the green light comes on and goes out when the beams 
are blocked and unblocked respectively.  Correct any faults before proceeding. 
 
 
 
 
 
 
 
 
 
 
 
 

Time delay

 is the only adjustment on the LO-21K.  It is changed by dipswitches 1 through 5, located on the front of 

the unit and can be set to achieve a 0 to 31 second delay.  The time delay must be set so that the red light on the 
LO-21K remains on for the entire closing cycle.  As soon as the door reaches the jamb, the red light should go out.  
The time delay will not begin until the motor begins rotating in a direction that allows door to close.  If motor rotation 
stops, the time delay will not stop counting down.  Interruption of the time delay will only result if re-activation of the 
door is recognized or the SBK-111 safety beams were broken.  Therefore, if the closing speed of the door is 
changed, the time delay on the LO-21K must also be adjusted to accommodate the time difference for the duration 
of the closing cycle. 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

Time 

Delay 

(sec) 

dip 1 

1 sec 

dip 2 

2 sec 

dip 3 

4 sec 

dip 4 

8 sec 

dip 5 

16 

sec 

 

Time 

Delay 

(sec) 

dip 1 

1 sec 

dip 2 

2 sec 

dip 3 

4 sec 

dip 4 

8 sec 

dip 5 

16 sec 

ON

 

OFF

 

OFF

 

OFF

 

OFF

 

 

17 

ON

 

OFF

 

OFF

 

OFF

 

ON

 

OFF

 

ON

 

OFF

 

OFF

 

OFF

 

 

18 

OFF

 

ON

 

OFF

 

OFF

 

ON

 

ON

 

ON

 

OFF

 

OFF

 

OFF

 

 

19 

ON

 

ON

 

OFF

 

OFF

 

ON

 

OFF

 

OFF

 

ON

 

OFF

 

OFF

 

 

20 

OFF

 

OFF

 

ON

 

OFF

 

ON

 

ON

 

OFF

 

ON

 

OFF

 

OFF

 

 

21 

ON

 

OFF

 

ON

 

OFF

 

ON

 

OFF

 

ON

 

ON

 

OFF

 

OFF

 

 

22 

OFF

 

ON

 

ON

 

OFF

 

ON

 

ON

 

ON

 

ON

 

OFF

 

OFF

 

 

23 

ON

 

ON

 

ON

 

OFF

 

ON

 

OFF

 

OFF

 

OFF

 

ON

 

OFF

 

 

24 

OFF

 

OFF

 

OFF

 

ON

 

ON

 

ON

 

OFF

 

OFF

 

ON

 

OFF

 

 

25 

ON

 

OFF

 

OFF

 

ON

 

ON

 

10 

OFF

 

ON

 

OFF

 

ON

 

OFF

 

 

26 

OFF

 

ON

 

OFF

 

ON

 

ON

 

11 

ON

 

ON

 

OFF

 

ON

 

OFF

 

 

27 

ON

 

ON

 

OFF

 

ON

 

ON

 

12 

OFF

 

OFF

 

ON

 

ON

 

OFF

 

 

28 

OFF

 

OFF

 

ON

 

ON

 

ON

 

13 

ON

 

OFF

 

ON

 

ON

 

OFF

 

 

29 

ON

 

OFF

 

ON

 

ON

 

ON

 

14 

OFF

 

ON

 

ON

 

ON

 

OFF

 

 

30 

OFF

 

ON

 

ON

 

ON

 

ON

 

15 

ON

 

ON

 

ON

 

ON

 

OFF

 

 

31 

ON

 

ON

 

ON

 

ON

 

ON

 

16 

OFF

 

OFF

 

OFF

 

OFF

 

ON

 

 

Red LED corresponds with lockout 
time, and will illuminate when the 
door is in a closing cycle. 
 
Green LED illuminates upon 
detection signal from the lockout 
safety beams.  

Set the dipswitches 
according to the chart below 
to achieve the desired 
lockout time 
(7 Second Default) 

If the Bodyguard learns a “door closed” position, but does not execute a learn for the 
“open door position”, place the door to a hold open position. With a BEA remote control, 
unlock the Bodyguard, and with the door in the open position, press the Magic Wand key 
and then the number 2 – the Bodyguard should begin flashing green to signify a set-up. 
If it does not, this will be a quick indication that the improper data is being sent for the 
“open door” position. Check to insure that data exists on the data lines leading into the 
Bodyguard. In the full open position, voltage should be approximately 12 volts DC. 
Voltage should be approximately 7.8 volts DC while the door is closing, and 0 volts DC 
once closed. If it is not, check the data lines, as well as the LO-21K to Motor wires (red & 
black). Refer to the Bodyguard User’s Guide for further information if necessary. 

STOP 

OPERATION 
CONT.

 

OBSOLETE

Содержание LO-21K

Страница 1: ...reference the ANSI 156 10 standard Shut off all power going to the header before attempting any wiring procedures Maintain a clean safe environment when working in public areas Constantly be aware of pedestrian traffic around the door area Always stop pedestrian traffic through the doorway when performing tests that may result in unexpected reactions by the door Always check placement of all wirin...

Страница 2: ...and the BODYGUARD DK 12 will switch to a door open pattern Once the door starts to close the LO 21K will sense the reversing change of polarity of the motor and will inhibit the BODYGUARD DK 12 for the preset lock out time delay During this time the red LED at the sensor will be off In addition to providing communication to the BODYGUARD DK 12 the LO 21K provides a safety connection between the sa...

Страница 3: ...sing speed of the door is changed the time delay on the LO 21K must also be adjusted to accommodate the time difference for the duration of the closing cycle Time Delay sec dip 1 1 sec dip 2 2 sec dip 3 4 sec dip 4 8 sec dip 5 16 sec Time Delay sec dip 1 1 sec dip 2 2 sec dip 3 4 sec dip 4 8 sec dip 5 16 sec 1 ON OFF OFF OFF OFF 17 ON OFF OFF OFF ON 2 OFF ON OFF OFF OFF 18 OFF ON OFF OFF ON 3 ON O...

Страница 4: ...res at the Bodyguard DK 12 3 Check continuity on the data wires red wire and red white striped wire Green LED does not come on when safety beams are blocked 1 Faulty safety beam receiver 2 Faulty connection on purple and gray wire from LO 21K 1 Test beams and LO 21K with multi meter 2 Perform continuity test on purple and gray wires Improper voltage reading on data lines at LO 21K 1 Incorrect wiri...

Отзывы: