Page 2 of 4
75.5355.04 FALCON EX 20190822
Page 2 of 4
75.5355.04 FALCON EX 20190822
1
3
2
FALCON EX
Mounting height:
16 ft
FALCON EXWIDE
Mounting height:
11.5 ft
FALCON EXXL
Mounting height:
8 ft
• The sensor must be firmly fastened in order not to vibrate.
• The sensor must not be placed directly behind a panel or any kind of material.
• The sensor must not have any object likely to move or vibrate in its sensing field.
• The sensor must not have any fluorescent lighting in its sensing field.
RED
US
red
black
white
green
yellow
EURO
green
brown
white
yellow
gray
BLACK
WHITE
GREEN
YELLOW
To access push buttons, you must open the sensor (see image, right):
a) Using a hex key, loosen the set screw located on the side of the housing.
b) Unscrew the housing cover.
Maximum angle
(+30° above horizon)
Minimum angle
(-90° below horizon)
European wire color cross-reference:
a) Bolt the bracket securely to the wall or other rigid surface.
Make sure that the two
5
⁄
16
- 18 Allen head bolts are loose so that the sensor can rotate freely.
b) Rotate the sensor to the appropriate angle for the application. When the bracket rotates, it will click. Every
click represents a 7
1
⁄
2
’’ angle adjustment.
c) Lock the angle adjustment by tightening the two
5
⁄
16
- 18 Allen head bolts.
Horizontal angle adjustments can be made by loosening the mounting bolts on the base and twisting to the
desired angle.
MOUNTING
DETECTION FIELD DIMENSIONS
WIRING
INSTALLATION TIPS
COM
NO
12-24 VAC/VDC
NC
Set
screw
Connect the wires to the door controller.
Choose between NO and NC contact.