BEA FALCON EX Скачать руководство пользователя страница 1

75.5355.04 FALCON EX 20190822   

Page 1 of 4

75.5355.04 FALCON EX 20190822   

Page 1 of 4

FALCON EX

3

1

2

Motion Sensor with Explosion-Proof Housing 

for Industrial Doors

1.  Explosion-proof housing
2.  Microwave sensor
3.  Adjustable bracket

FALCON EX:  for normal to high mounting (11.5 - 23 ft) 

FALCON EXXL:  for low mounting (6.5 - 11.5 ft)

FALCON EXWIDE:  for wide detection field

MICROWAVE SENSOR SPECIFICATIONS

Technology:

microwave doppler radar

Transmitter frequency:

24.150 GHz

Transmitter radiated power:

< 20 dBm EIRP

Transmitter power density:

< 5 mW/cm

2

Mounting height:

FALCON EX: 11.5 − 23 ft; FALCON EXXL: 6.5 − 11.5 ft; 

FALCON EXWIDE: 11.5 − 21 ft

Detection zone:

FALCON EX: 13 x 16 ft @ 16ft; FALCON EXXL: 13 x 6.5 ft @ 8.2 ft

FALCON EXWIDE: 30 x 11ft @ 21ft. (typical at 30° and field size 9)

Min. detection speed:

2 in/s*

Supply voltage:

12 − 24 VAC ±10%; 12 − 24 VDC +30% / -10%

Mains frequency:

50 − 60 Hz

Power consumption:

< 2W

Output:

max. contact voltage:

max. contact current:

max. switching power:

relay (free of potential change-over contact)

42V AC/DC

1A (resistive)

30 W (DC) / 60 VA(AC)

Temperature range:

-22 − 140 °F

Housing certification:

(Adalet / Scott Fetzer Co., UL Listing # E81696)

UL Class I, Group BCD; Class II, Group EFG; Class III;

CENELEC:  EExd IIC, IP66, NEMA 4x; 7BCD, 9EFG

Dimensions:

9 in (L) x 7.5 in (W) x 5.5 in (H)

Tilt adjustment angle:

-90 − 30° in elevation

Materials:

Copper-free aluminum (Housing); Powder-coated steel (Bracket)

Weight:

10 lbs

Cable length:

100 ft (FALCON EX100, FALCON EXXL100, FALCON EXWIDE)

30 ft (FALCON EX, FALCON EXXL)

Cable diameter:

1

4

” max

Electrical Access:

3

4

” NPT pipe thread

Norm conformity:

R&TTE 1999/5/EC; EMC 2004/108/EC

Specifications are subject to change without prior notice.

All values measured in specific conditions.

DESCRIPTION

ENGLISH

* Measured in optimal conditions

Visit website for 
available languages of 
this document.

Содержание FALCON EX

Страница 1: ...ly voltage 12 24 VAC 10 12 24 VDC 30 10 Mains frequency 50 60 Hz Power consumption 2W Output max contact voltage max contact current max switching power relay free of potential change over contact 42V AC DC 1A resistive 30 W DC 60 VA AC Temperature range 22 140 F Housing certification Adalet Scott Fetzer Co UL Listing E81696 UL Class I Group BCD Class II Group EFG Class III CENELEC EExd IIC IP66 N...

Страница 2: ... key loosen the set screw located on the side of the housing b Unscrew the housing cover Maximum angle 30 above horizon Minimum angle 90 below horizon European wire color cross reference a Bolt the bracket securely to the wall or other rigid surface Make sure that the two 5 16 18 Allen head bolts are loose so that the sensor can rotate freely b Rotate the sensor to the appropriate angle for the ap...

Страница 3: ...ON FILTER bi two way detection uni one way detection towards sensor uni AWAY one way detection away from sensor A active output relay energizes upon detection P passive output relay de energizes upon detection Choose the correct detection filter for your application with the remote control or push buttons Detection of all targets pedestrians and parallel traffic are detected 1 no specific filter 2...

Страница 4: ...l for the given application Increase detection filter value Decrease sensor angle Increase mounting height Ensure detection mode is unidirectional LED flashes quickly after unlocking Sensor needs access code to unlock Enter correct access code If you forgot the code cycle the power to access the sensor without access code Change or delete the access code Sensor does not respond to the remote contr...

Отзывы: