 - 3 Relay Sequence (MC35)

75.5501.02  EN   20091102   (75.5500)   

 

 

 

 

 

 

 

 

Page 10 of 15

G

N

D

IN

-1

G

N

D

IN

-2

G

N

D

IN

-3

G

N

D

IN

-4

1

2

3

4

WET

WET

WET

N

C

N

O

C

O

M

N

C

N

O

C

O

M

12

-2

4V

AC

/D

C

RELAYS

1

2

POWER

RELAY 1

IN

C

R

.

PARAM

SETUP

D

C

AC

D

R

Y

W

ET

INPUTS

3 5

N

C

N

O

C

O

M

3

Br

3

CAUTION:  RELAY 1 WET 

OUTPUT OPTION 

IS ACTIVE FOR 

ALL FUNCTIONS.

12 to 24

 VAC/VDC

+/- 10%

To Activation

Circuit of 

Door Control 

1

Pushplate or other 

Dry Contact Device.

‘WET’ 

12 to 24

 VAC/VDC

+/- 10%

INPUT

+      -

Typically Connected to 

Lock Device.  When DC ‘WET’

Output is Selected for Relay 1,

COM Terminal is Positive (+).

To Activation

Circuit of 

Door Control 

2

  The MC35 function provides a sequence for Relay 1 and/or 

Relay 2 and/or Relay 3 triggered by Input 1 or ‘WET’ Input.  

Simply put this function is a MC25 with three relays instead of 

two.  Adjustable parameters include 

H1

 for activation hold time of 

Relay 1, 

H2

 for activation hold time of Relay 2, 

H3

 for activation 

hold time of Relay 3, 

D1

 for delay between activation of Relay 1 to 

Relay 2 and 

D2

 for delay between activation of Relay 1 to Relay 

3.  A re-activation of Input 1 or ‘WET’ Input before the sequence 

expires will re-start all hold timers and keep the relays active.  

A maintained input will freeze all hold timers thus keeping their 

relays active until the input is released, which will allow the hold 

timers to expire and deactivate the relays normally.

  

NOTE

:  The delay timer will only fire one time during initial 

activation or maintained input.

A typical application is a secure pair of doors with flush bolts in 

which you have a push-plate to start the sequence to unlock 

the security device, such as a Maglock or electric strike, then 

activate the first door controller and then activate the second 

door controller.  For this scenario the push-plate would be wired 

to Input 1, the security device would be wired to Relay 1, the first 

door controller would be wired to Relay 2 and the second door 

controller would be wired to Relay 3.

NOTE:   While the ‘WET’ Input is not involved in our typical 

application, it will still function as Input 1 does if used.

MC35 SETUP

1.  Wire the Br3 accordingly.

2.  Select the MC35 as the function according to the steps outlined in Section 5 – Selecting the Function.

•  Press and hold both push buttons (INCR & PARAM) for three (3) seconds to activate the display.

•  Press the INCR button to toggle through each function and select 

35

.

3.  Set the MC35 parameters according to the steps outlined in Section 5 – Selecting the Function.  

•  Press PARAM button to cycle through and set the parameters.

•  Press the INCR button to increment the parameter’s value.

Parameters for the MC35 function are shown in the chart.  Set the parameters as needed for the application, and wait for the display to 

become inactive to save the configuration.

PARAMETER

(PARAM Button)

DESCRIPTION

POSSIBLE VALUES

     (INCR Button)

H1

Relay 1 hold time

00

’ through ‘

60

’ - Relay 1 hold time will not begin counting down until the release of Input 1 or 

‘WET’ Input.

H2

Relay 2 hold time

00

’ through ‘

60

’ - Relay 2 hold time will not begin counting down until the delay between 

Relay 1 and Relay 2 expires.

H3

Relay 3 hold time

00

’ through ‘

60

’ - Relay 3 hold time will not begin counting down until the delay between 

Relay 1 and Relay 3 expires.

D1

Delay between 

Relay 1 and Relay 2

00

’, ‘_

1

’ (1/4), ‘_

2

’ (1/2), ‘_

3

’ (3/4), ‘

01

’ through ‘

60

’ seconds. The delay time will begin 

counting down with the activation of the sequence.

D2

Delay between 

Relay 1 and Relay 3

00

’, ‘_

1

’ (1/4), ‘_

2

’ (1/2), ‘_

3

’ (3/4), ‘

01

’ through ‘

60

’ seconds. The delay time will begin 

counting down with the activation of the sequence.

4.  Once programming is complete, test the Br3.   Trigger the sequence via Input 1 or ‘WET’ Input.  Ensure that the sequence runs and the 

relays activate and the timers are as programmed.  The display will show 

R1

 when Relay 1 is energized, 

R2

 when Relay 2 is energized, 

R3

 

when Relay 3 is energized, 

R=

 when Relay 1 and Relay 2 are energized at the same time, 

  when all three relays are energized or 

R=

 when 

Relay 1 and Relay 3 are energized at the same time.

5.  Upon completion of the above steps, walk test the door to ensure all functions, timers, sensors, etc. are working as intended and that the 

system is in compliance with all applicable standards (i.e. ANSI A156.10, A156.19).

Содержание Br3

Страница 1: ...n switch input for which closing it will re inhibit Input 1 Simply put this function is a combination between a LE21 and MC25 6 2 5 MC25 2 Relay Sequence Provides a sequence for Relay 1 and or Relay 2 triggered by Input 1 or WET Input 7 2 8 MC28 2 Relay Sequence w Door Position Input Provides a sequence for Relay 1 and or Relay 2 triggered by Input 1 or WET Input Additionally Input 2 provides a do...

Страница 2: ...IPTION SPECIFICATION Supply Voltage 12 to 24 VAC VDC 10 Contact Rating DRY Relay 1 Relay 2 Relay 3 Contact Rating WET Relay 1 3 A at 24 VAC 3 A at 30 VDC 3 A at 24 VAC 3 A at 30 VDC 1 A at 24 VAC 1 A at 30 VDC 1 A Current Consumption 30 to 130 mA DRY Output Temperature Range 15 F 26 C to 150 F 65 C Dimensions 5 2 133mm W x 2 2 55mm D x 1 25mm H Input Specification Inputs 1 to 4 DRY Contact WET Inp...

Страница 3: ...long as no relays are active the display will show the function selected otherwise it will show those relays Once the values are changed they are only saved after the display goes inactive again 5 seconds NOTE Remember that the INCR push button always increments the value of the parameter that you are looking at and the PARAM push button toggles through the available parameters NOTE To change only...

Страница 4: ...system is in compliance with all applicable standards i e ANSI A156 10 A156 19 75 5501 02 EN 20091102 75 5500 Page 4 of 15 6A Function 10 Timer Module MC10 GND IN 1 GND IN 2 GND IN 3 GND IN 4 1 2 3 4 WET WET WET NC NO COM NC NO COM 12 24V AC DC RELAYS 1 2 POWER RELAY 1 INCR PARAM SETUP DC AC DRY WET INPUTS 1 0 NC NO COM 3 Br3 CAUTION RELAY 1 WET OUTPUT OPTION IS ACTIVE FOR ALL FUNCTIONS 12 to 24 V...

Страница 5: ...le parameter for the LE21 function is shown in the chart Set it as needed for the application and wait for the display to become inactive to save the configuration PARAMETER PARAM Button DESCRIPTION POSSIBLE VALUES INCR Button H1 Relay 1 hold time 00 through 60 Relay 1 hold time will not begin counting down until the release of an activation input 4 Once programming is complete test the Br3 Attemp...

Страница 6: ...M button to cycle through and set the parameters Press the INCR button to increment the parameter s value Parameters for the LE22 function are shown in the chart Set the parameters as needed for the application and wait for the display to become inactive to save the configuration PARAMETER PARAM Button DESCRIPTION POSSIBLE VALUES INCR Button H1 Relay 1 hold time 00 through 60 Relay 1 hold time wil...

Страница 7: ...ding to the steps outlined in Section 5 Selecting the Function Press PARAM button to cycle through and set the parameters Press the INCR button to increment the parameter s value Parameters for the MC25 function are shown in the chart Set the parameters as needed for the application and wait for the display to become inactive to save the configuration PARAMETER PARAM Button DESCRIPTION POSSIBLE VA...

Страница 8: ...ers Press the INCR button to increment the parameter s value Parameters for the MC28 function are shown in the chart Set the parameters as needed for the application and wait for the display to become inactive to save the configuration PARAMETER PARAM Button DESCRIPTION POSSIBLE VALUES INCR Button H1 Relay 1 hold time 00 through 60 Relay 1 hold time will not begin counting down until the release o...

Страница 9: ...METER PARAM Button DESCRIPTION POSSIBLE VALUES INCR Button H1 Relay 1 hold time 00 through 60 Relay 1 hold time will not begin counting down until the release of Input 2 H2 Relay 2 hold time 00 through 60 Relay 2 hold time will not begin counting down until the delay between Relay 1 and Relay 2 expires D1 Delay between Relay 1 and Relay 2 00 _1 1 4 _2 1 2 _3 3 4 01 through 60 seconds The delay tim...

Страница 10: ... application it will still function as Input 1 does if used MC35 SETUP 1 Wire the Br3 accordingly 2 Select the MC35 as the function according to the steps outlined in Section 5 Selecting the Function Press and hold both push buttons INCR PARAM for three 3 seconds to activate the display Press the INCR button to toggle through each function and select 35 3 Set the MC35 parameters according to the s...

Страница 11: ...ay to become inactive to save the configuration PARAMETER PARAM Button DESCRIPTION POSSIBLE VALUES INCR Button H1 Relay 1 hold time 00 through 60 Relay 1 hold time will not begin counting down until the release of Input 1 H2 Relay 2 hold time 00 through 60 Relay 2 hold time will not begin counting down until the release of Input 2 4 Once programming is complete test the Br3 Wait until both doors a...

Страница 12: ...set for the MC55 as the state of Relay 1 and Relay 2 are not based on time so just wait for the display to become inactive to save the configuration 4 Once programming is complete test the Br3 Wait until both doors are closed then trigger Relay 1 via Input 1 Ensure that Relay 1 changes state and that is maintained The display will show R1 when Relay 1 is energized Test the interlock by attempting ...

Страница 13: ...n to increment the parameter s value Parameters for the MC65 function are shown in the chart Set the parameters as needed for the application and wait for the display to become inactive to save the configuration PARAMETER PARAM Button DESCRIPTION POSSIBLE VALUES INCR Button H1 Relay 1 hold time 00 through 60 Relay 1 hold time will not begin counting down until the release of Input 1 for inbound or...

Страница 14: ...e Function Press PARAM button to cycle through and set the parameters Press the INCR button to increment the parameter s value Parameters for the MC75 function are shown in the chart Set the parameters as needed for the application and wait for the display to become inactive to save the configuration PARAMETER PARAM Button DESCRIPTION POSSIBLE VALUES INCR Button H1 Relay 1 hold time 00 through 60 ...

Страница 15: ...programmed 3 Jumper an active Input and ensure that the fault is not within the wiring If module works when jumped trace wiring from Inputs relays 4 Replace module Module reacts to input but has no output 1 Wrong outputs are connected 2 Incorrect wiring 3 Incorrect jumper settings 4 Faulty module 1 Check to ensure that the proper outputs are connected per the function selected 2 Trace all wiring t...

Отзывы: