USER INTERFACE
DIP switches can be set to achieve desired functionality based upon specific application requirements.
Potentiometers control output relay functionality.
900 MHz wireless transmitters can be programmed (or "learned") as either
UNSECURE
or
SECURE
transmitters.
Any combination of up to 75 transmitters may be programmed.
Pressing and holding transmitter button for three (3) seconds activates signal strength LED on Br2-900.
DIP-Switches
DIP
STATUS
FUNCTION
DESCRIPTION
1
STD
standard
mode
allows only learned/programmed transmitters to function
UNI
1
universal
mode
2
allows learned/programmed and "universal transmitters" to function
2
STD
standard
mode
pressing/holding or pressing/releasing transmitter activates and holds
relay according to HOLD TIME POTs (single shot)
EH
extended
hold
pressing/holding transmitter holds relay as long as transmitter is pressed/
held – once released, relay acts according to HOLD TIME POTs
NOTES:
1. Day/Night mode does not function when DIP-switch 1 is set to UNI.
2. See Universal Mode in SET-UP section (page 5).
Potentiometers
Learn Buttons
BUTTON
FUNCTION
DESCRIPTION
UNSECURE
unsecure transmitters
learned transmitter functions when INPUT D/N is open or closed
SECURE
secure transmitters
learned transmitter only functions when INPUT D/N is open
POT
FUNCTION
DESCRIPTION
HOLD 1
relay 1 hold time
0.5 – 10 seconds
HOLD 2
relay 2 hold time
0.5 – 10 seconds
DELAY
delay between relay 1 and relay 2
0 – 3 seconds
Signal Strength Indicator
LED COLOR
DESCRIPTION
GREEN
strong
wireless signal
YELLOW
moderate
wireless signal
RED
weak
wireless signal