SIZE:
DRAWN BY:
TITLE: PARALLINK, DOROMATIC
ASTRO SWING CONTROL
A
NOTES: 1) OPTIONAL AUX. SWITCH SHOULD OPEN AT APPROX. 65-70 DEGREES. SET CONTROL FUNCTION DIAL TO 6. IF NOT
USED. BEA RECOMMENDS CONTROL FUNCTION DIAL SET TO 5.
2) RH MOTOR SHOWN, REVERSE MOTOR SWITCH ON PARALLINK FOR LH MOTOR.
3) BODYGUARD MUST BE PROGRAMMED TO RELAY VALUE 2. DEFAULT IS 1.
4) IF DOROMATIC INTERFACE CABLE & CHIP IS PREVIOUSLY INSTALLED. IT MUST BE REMOVED.
100 ENTERPRISE DRIVE
PITTSBURGH, PA 15275
PHONE: (412) 249-4100
FAX: (412) 249-4101
EMAIL: www.beasensors.com
REV BY:
KJG
TUC
80.0220.01
SCALE:
DATE:
NONE
12SEP2005
PART NO:
SHEET
1 OF 1
Common
N/O
N/C
AUXILIARY
SWITCH
PUSH TO TEST
BODYGUARD (See Note #3)
ASTROSWING
CONTROL
IF AFTER TROUBLESHOOTING A PROBLEM, A SATISFACTORY SOLUTION CANNOT BE ACHIEVED, PLEASE CALL B.E.A., INC.
FOR FURTHER ASSISTANCE DURING EASTERN STANDARD TIME AT 1-800-523-2462 FROM 8AM - 5PM. FOR AFTER-HOURS,
CALL EAST COAST: 1-866-836-1863 OR 1-800-407-4545 / MID-WEST: 1-888-308-8843 / WEST COAST: 1-888-419-2564. DO NOT
LEAVE ANY PROBLEM UNRESOLVED. IF YOU MUST WAIT FOR THE FOLLOWING WORKDAY TO CALL B.E.A., LEAVE THE
DOOR INOPERABLE UNTIL SATISFACTORY REPAIRS CAN BE MADE. NEVER SACRIFICE THE SAFE OPERATION OF THE
AUTOMATIC DOOR OR GATE FOR AN INCOMPLETE SOLUTION.WEB: WWW.BEASENSORS.COM