LOCK STATUS RELAY CONTACTS (SPDT)
- Relay dry contacts are rated 1A at 24 VDC for safe operation,
DO NOT exceed this rating.
- If a NO switch is required, connect the wires from the system to
Terminal 3 and Terminal 4.
- If a NC switch is required, connect the wires from the system to
Terminal 4 and Terminal 5.
DOOR STATUS SWITCH
- Connect the positive (+) lead from the power source to the
black wire of the Door Status Sensor switch.
- Connect the negative (-) lead from the power source to one
end of the light for door status.
- Connect the red or green wire of the Door Status Sensor switch
to the other end of the light for door status.
red = light off with door closed
green = light on with door closed
- The reed switch dry contacts are rated at 3W (switching contact
0.25 amps max, switching voltage 30VDC max; resistive load)
for safe operation.
7 Installation
–
Electrical (cont.)
G
R A V
R
V
A
B
1 2 3 4 5
+ - NO C NC
12VDC
24VDC
POWER
SELECTOR
JUMPER
0 - 90 SEC.
RELOCK TIMER
POWER
SUPPLY
LOCK STATUS RELAY (SPDT)
SWITCHES (optional)
1
PCB
2
sw
+
-
NC
COM
NO
1
PCB
2
MAGNETIC LOCK
NC
RED
GREEN
BLACK
LIGHT
COM
REED SWITCH
ON
DOOR STATUS SENSOR SWITCH*
* Switch changes state when door is open
NO
BEA Inc., the sensor manufacturer, cannot be held responsible for incorrect installations or incorrect adjustments of the sensor/device; therefore, BEA Inc. does not
guarantee any use of the sensor/device outside its intended purpose.
BEA Inc. strongly recommends that installation and service technicians be AAADM-certifi ed for pedestrian doors, IDA-certifi ed for doors/gates, and factory-trained for the
type of door/gate system.
Installers and service personnel are responsible for executing a risk assessment following each installation/service performed, ensuring that the sensor/device system
performance is compliant with local, national, and international regulations, codes, and standards.
Once installation or service work is complete, a safety inspection of the system shall be performed and documented per the manufacturer’s recommendations or industry
guidelines. Examples of compliance may apply to ANSI 156.10, ANSI 156.19, ANSI/DASMA 102, ANSI/DASMA 107, UL294, UL325, and International Building Code.
BEA, INC. INSTALLATION/SERVICE COMPLIANCE EXPECTATIONS
Tech Support & Customer Service: 1-800-523-2462 | General Tech Questions: [email protected] | Tech Docs: www.BEAsensors.com