9 Company Contact
8 User Operation
7 Additional Procedures
red
red
red flashing
red flashing
red flashing
red flashing
red flashing
red flashing
DOOR MODE
green
green
green
green
OPTIONAL: Door bell and tamper alarm
4a) Door bell:
a. Connect an external speaker (8Ω, 0.5w) to brown/white and black/white wires of this device.
b. Press the star (*) key and the external speaker rings as a door bell.
4b) External tamper alarm:
This feature allows a built-in buzzer to activate if the keypad is removed from the wall. The alarm will stop
automatically in 60 seconds or if the admin code is entered before the 60-second timeout.
FACTORY DEFAULT: OFF
a. To turn on the tamper alarm feature, enter “setup” mode.
b. Press the star (*) key and then “6”. Mode LED will flash red.
c. Press “0” and then “2”. A long beep will sound. Mode LED will turn red.
d. Press “#” again to exit “setup” mode. Mode LED turns green.
a. To turn off the tamper alarm, enter “setup” mode.
b. Press the star (*) key and then “6”. Mode LED will flash red.
c. Press “0” and then “1”. A long beep will sound. Mode LED will turn red.
d. Press “#” again to exit “setup” mode. Mode LED turns green.
OPTIONAL: Remove all user codes
a. Enter “setup” mode.
b. Press the star (*) key and then “8”. Mode LED will flash red.
c. Press “8” twice. A long beep will sound. Mode LED will flash red.
d. Press “#” again to exit “setup” mode. Mode LED turns green
OPTIONAL: Restore to factory defaults
a. Enter “setup” mode.
b. Press the star (*) key and then “8”. Mode LED will flash red.
c. Press “9” twice. A long beep will sound. Mode LED will flash red.
d. Press “#” again to exit “setup” mode. Mode LED turns green
Simply enter the user code provided to you.
If 3 invalid consecutive keyboard input entries occur, the keypad will be disabled for 60 seconds.