background image

Rainbow 72 R NBC- Filtration & Ventilation System

Rainbow 72 R

  Ventilation and Air Filtration System 

for a Residential Safe Room · 

www.beind.co.il

5 | 

Principle of system operation

When the system is operating according to the instructions, air is introduced to the room 

via the air inlet valve and the NBC filter 

(2)

. The filtered air is circulated through the room 

and creates an overpressure, thus preventing the entry of polluted air through crevices 

or concealed openings

When the room is in a state of overpressure, the indicator vane 

(7)

 spins around. In this 

state, it is possible to remain in the room without the personal NBC masks (on condition 

that the room is not contaminated by NBC before operating the system). Overpressure 

created in the room is not harmful to humans and pets.

The following illustration displays the parts of the system and their location in a 

residential safety room:

nciple of system operation

2

7

4

6

5

8

1

Indicator vane 

mounted on 

pressure relief 

valve

Содержание Rainbow 72 R

Страница 1: ...2110 2015 NATO Supplier No 1532A RAINBOW Air ventilation and filtration systems Beth El Industries Approved by the Civil Defense Command and the Standards Institution of Israel In accordance with Isra...

Страница 2: ...e Safety Instructions 3 System Parts List 4 System s Principle of Operation 5 System s Operation in Filtration mode 6 System s Operation in Ventilation mode 10 Filter Handling Routine Storage 11 Troub...

Страница 3: ...Use the system only in accordance with the instructions in this manual 2 The system must not be used for any purpose other than for the purpose of ventilation and filtration of a residential safety r...

Страница 4: ...tem cover 2 CBRN filter including adapter for ventilation 3 Air inlet blast valve with prefilter 4 Connection hose for manual blower 5 Electrical blower 6 Manual blower 7 Air outlet overpressure blast...

Страница 5: ...hus preventing the entry of polluted air through crevices or concealed openings When the room is in a state of overpressure the indicator vane 7 spins around In this state it is possible to remain in...

Страница 6: ...s required 1 Remove the system cover Grasp both handles on the sides of the cover and pull it towards you Observe the quickstart guide operating instructions on the inner wall of the system cover 2 Sl...

Страница 7: ...ove the manual pump from the cabinet 1 Remove the electric blower To remove the blower lift it upwards until it exits the holder 2 7 Connect the electric blower to the filter opening 8 Connect the pow...

Страница 8: ...alternating pull and push action 3 Run at 40 cycles per minute making sure the indicator vane spins Operation with a manual blower In the event of a power failure or in cases of other problems with th...

Страница 9: ...on pages 6 7 2 Make sure that the other end of the connecting pipe is connected to the air outlet opening in the filter 1 Attach the manual blower to the bracket using the connecting pins Adjust the b...

Страница 10: ...ver 1 2 2 Loosen the strap of the filter and remove the venti lation adapter Tighten the filter back into place using the strap 3 Remove the inlet valve cover and place instead the adapter for ventila...

Страница 11: ...there was no NBC attack but the filter was attached to the wall nonetheless it is possible to detach it from the valve to close the openings with the sealing caps and to arrange for a service check o...

Страница 12: ...propriate opening in the filter adapter for the manual blower The filter does not fit in the inlet valve a Make sure you hold the filter in the correct direction with the blue arrow on the sticker on...

Отзывы: