background image

Rainbow 36 V NBC-Filtration & Ventilation System

Rainbow 36 V 

 Ventilation and Air Filtration System 

for a Residential Safe Room 

·

 

www.beind.co.il

3  

|

 

Dear Customer,

Installing the 

Rainbow 36 V

 Ventilation and Air Filtration System in your 

home can save the lives of you and your loved ones.

For your security, we recommend carefully reading this manual, as well as 
watching the training film on the company’s website. Keep this manual in an 
appropriate place, so that it will be available in the event of an emergency.

It is also recommended to practice operating the system from time to time, 

but without removing the filter’s sealing caps and without attaching 
the filter!

Safety Instructions

1.  Use the system only in accordance with the instructions in this manual.

2.  Do not use the system for any purpose other than for ventilation and 

filtration of a residential safety room, and protection from biological and 
chemical warfare substances while staying in the safety room.

3.  Only connect the system to the standard voltage outlet of a residencal 

home (230 VAC). Other types of power supplies are liable to cause damage 
to the system and will compromise proper functioning.

4.  Protect the system from extreme weather conditions and moisture.

5.  Store the system out of the reach of children. Do not allow a child under 

the age of 10 to operate the system.

6.  Any repairs, including disassembly for repairs, should be performed by 

professional technicians that are approved by Beth-El Industries, and 
according to the details in the warranty. 

7.  By recommendation of the Civil Defense Command, arrange a periodic 

service visit once every two years in order to ensure the suitability of the 
safety room and the proper functioning of the system.

Содержание Rainbow 36 V

Страница 1: ...ystems Approved by the Civil Defense Command and the Standards Institution of Israel In accordance with Israel Standard 4570 Beth El Industries Rainbow 36 V User s Manual Ventilation Air Filtration Sy...

Страница 2: ...ww beind co il 2 Table of Contents Page Safety Instructions 3 System Parts List 4 System s Principle of Operation 6 Using the System 8 Routine Storage 10 Troubleshooting 11 Contact Information back co...

Страница 3: ...o not use the system for any purpose other than for ventilation and filtration of a residential safety room and protection from biological and chemical warfare substances while staying in the safety r...

Страница 4: ...il 4 System Parts List System cover Air inlet valve Connecting hose Electric blower Manual blower NBC filter Installed on the air inlet valve Indicator vane Installed on the overpressure blast valve B...

Страница 5: ...enings When the room is in a state of overpressure the indicator vane 2 spins around In this state it is possible to remain in the room without the personal NBC masks on condition that the room is not...

Страница 6: ...plumbing air conditioning water and sewage in the event that they are available in the residential safety room are sealed adequately Step 1 Remove the system cover Grasp the two handles on the sides...

Страница 7: ...wall outlet 1 Press the operating switch on the blower 2 Wait a few seconds for the blower to start working Attention The indicator vane on the air outlet valve will start to spin after a few seconds...

Страница 8: ...e positions First Position Attaching the manual blower directly to the filter In a residential safety room in which there is an air inlet valve located at a height below 1 6 meters Remove the manual b...

Страница 9: ...he flexible hose 2 to it Attach the bracket to the adapter on the wall by means of sliding the bottom of the tabs into the appropriate slots as much as possible 3 Be sure that the other end of the con...

Страница 10: ...emergency situation the company should be summoned for a service check and maintenance of the filter If there was no NBC attack but the filter was attached to the wall nonetheless it is possible to de...

Страница 11: ...e opening of the filter and blower The filter doesn t fit into its location in the inlet valve A Make sure that you are holding the filter in the proper direction with the blue arrow on the label of t...

Страница 12: ...Telephone 04 629 9988 E mail Rainbow beind co il Beth El Zikhron Yaaqov Industries Ltd 1 Avshalom Road P O Box 166 ZikhronYaaqov 3095101 Israel Tel 972 4 629 9999 israel beind com www beind co il rain...

Отзывы: