3. Pull the recoil starter handle slowly until passing the compression point
(resistance will be felt), then return the handle to its original position
and pull briskly.
starting
your
generator
4. After starting, allow the recoil starter handle to return to its original
position with the handle still in your hand.
NOTE:
If the engine fails to start after several attempts, repeat the starting
procedures mentioned above with the engine choke switch placed in the
OFF position.
5. After 20 to 30 seconds of warm-up is completed, turn the engine
choke switch to “OFF” position.
7. Test the GFCI receptacle on the unit. Push the test button. The reset
button should pop out and there should be no power at the receptacle.
Apply a test load or lamp to each receptacle to verify. IF THE RESET
BUTTON DOES NOT POP OUT, DO NOT USE THE RECEPTACLE.
SEE SERVICE PROVIDER FOR SERVICE IMMEDIATELY.
8. If GFCI receptacle tests correctly, firmly push the reset button to
restore power. A distinctive click should be heard or felt when this is
complete. IF THE RECEPTACLE DOES NOT RESET PROPERLY, DO
NOT USE THE RECEPTACLE. SEE SERVICE PROVIDER FOR
SERVICE IMMEDIATELY.
9. Loads can now be applied to unit.