be bionic steeper Скачать руководство пользователя страница 17

17

A bebionic system is very versatile and allows a number of different power and connectivity options.

Most options are detailed in the following section of this document. However if you have a question regarding a 

specific build not outlined in this document please contact your local supplier.

The bebionic hand may also be used with other manufacturers’ electrodes and wrists. This means the bebionic 

small hand can be fitted into an existing system without having to change every single component.

4.0 Connections and Compatability

4.1 Wrist Options

Thee are currently three wrist options for the bebionic small hand.

Electric Quick                     

Disconnect (EQD)

 

Short Wrist 

Allows the hand to be removed 

with a rotating action. The EQD 

wrist allows the patient to quickly 

rotate and remove or attach 

terminal devices as required.

Low profile connector for 

applications where there is a 

long residual limb. A short wrist 

lamination assembly is supplied 

attached to these hands. The hand 

can be rotated against a constant 

friction, which can be adjusted by 

the patient.

Flexion Wrist 

The Flexion Wrist from Motion 

Control is a simple flexion device 

that allows the wearer to easily 

lock or unlock the wrist position 

and reposition the wrist in either a 

flexion or extension position. The 

mechanism allows the wrist to be 

flexed or extended to 30 degrees 

in either direction and locked in 

each of the three positions.

4.2 Battery Options

BBI=1300S

Typical Capacity: 1300mAh
Voltage (Nominal): 7.4V
Size:  8.6  x  36.5  x  66.5  mm  (x2)                                                       

(

3

4

” x 1 

3

8

” x 2 

5

8

”)

BBI=2200S

Supplied with a removable shrink 

fit coating, allowing the cells to be                 

split for easier fitting in the prosthesis.
Typical Capacity: 2200mAh
Voltage (Nominal): 7.4V
Size:  18.5 x 36.5 x 70 mm                                 

(

3

4

” x 

3

4

” x 2 

3

4

”)

or  18.5  x  18.5  x  70  mm  (x2  when  split)                                             

(

3

4

” x 1 

3

8

” x 2 

3

4

”)

Only the following battery options should be used with the bebionic 

small. Use of other battery systems is not recommended.

WARNING

Содержание steeper

Страница 1: ...Technical Manual small...

Страница 2: ...2...

Страница 3: ...3 3 Removing a bebionic Glove 4 0 Connections Compatibility 17 21 4 1 Wrist Options 4 2 Battery Options 4 3 Power Information 4 4 System Connections 4 5 System Compatibility 5 0 bebalance 23 31 5 1 In...

Страница 4: ...small tool kit 4 bebionic small user guide 5 bebionic small technical manual 6 bebalanceBT software CD 7 spare palp box 4 6 7 1 1 In the case Text with this symbol contain important safety information...

Страница 5: ...4 1 8 1 2 105mm 12mm 13oz 369g bebionic small hand with Short Wrist white BBHSM QD W F 4 1 8 2 105mm 53mm 16oz 460g bebionic small hand with Flex Wrist white BBHSM QD B 4 1 8 1 105mm 25mm 13 3 4 oz 3...

Страница 6: ...l of grip and speed Speed and grip force are set to maximum To alternate between the default and alternative grip pattern an OPEN OPEN signal must be applied i e the hand must be fully opened the sign...

Страница 7: ...o optimize the contact point of the thumb tip against the opposing finger s for Tripod Pinch and Precision Grips This is done by moving the thumb either towards the palm or away from the palm This adj...

Страница 8: ...until they meet resistance or the close signal stops This type of grip allows users to pick up hold and manipulate a variety of everyday objects such as car keys coins jar lids and pens Hook With the...

Страница 9: ...n active and under user control To achieve this grip it is necessary for the thumb to be manually repositioned by the practitioner technician so that the thumb only contacts the index finger Precision...

Страница 10: ...ly close The thumb then closes onto the side of the index finger The thumb position may be raised and lowered without moving the other four fingers allowing for release capture or reposition of the ob...

Страница 11: ...ddle and ring fingers providing stability The index finger closes on to the mouse button and then backs off to provide the button press Each close signal will give a mouse click whilst an open signal...

Страница 12: ...12...

Страница 13: ...e has been designed specifically for use with the bebionic hand The use of other gloves may damage the hand and will void the warranty CAUTION 3 0 bebionic Glove Care Take care when fitting and using...

Страница 14: ...he hand is in glove donning mode CAUTION Do not use talcum powder or lubricant when fitting the glove CAUTION 3 4 Press and hold the program switch for six seconds The hand will automatically drive in...

Страница 15: ...ressing the program switch for ap proximately three seconds Next put the hand into glove donning mode by pressing the pro gram switch for 4 seconds Roll up the base of the glove and pull the whole glo...

Страница 16: ...16...

Страница 17: ...there is a long residual limb A short wrist lamination assembly is supplied attached to these hands The hand can be rotated against a constant friction which can be adjusted by the patient Flexion Wri...

Страница 18: ...attery and requires an additional connector cable to link to the hand The connector cable for EQD hands as shown on page 28 is supplied with each battery For short wrist or friction wrist options a di...

Страница 19: ...to scale The system detailed below is suitable for a bebionic hand with an Electronic Quick Disconnect and Flex Wrist BBI 1300S bebionic 7 4V 1300mAh split cell battery BBI 2200S bebionic 7 4V 2200mA...

Страница 20: ...ly for hands with Short Wrist Components not to scale The system detailed below is suitable for a bebionic hand with a Short Wrist CBBHA72 connector cable BBI 1300S bebionic 7 4V 1300mAh split cell ba...

Страница 21: ...should confirm the warranty position with these manufacturers CAUTION Supplier Part Number Type of Input Steeper SteeperUSA ELEC50 and ELEC60 Myoelectrode Otto Bock 9X18 9X37 Switch Otto Bock 13E125...

Страница 22: ...22...

Страница 23: ...l if muscles produce limited or difficult to control signals as is often the case with higher level amputation With bebalanceBT the practitioner may adjust the operation of the electrode reset co cont...

Страница 24: ...cking on dotNetFx40_Full_x86_x64 exe Similarly the bluetooth dongle requires software to be installed to operate Specific versions can be found in the BLED112 Windows Driver Folder If using a retro op...

Страница 25: ...hand must be switched ON whereas in glove donning mode the hand must be switched OFF The BT communication can be disabled by pressing the button on the back of the hand for longer than two seconds Al...

Страница 26: ...ip and alternative grip apply a further OPEN signal within variable time up to two seconds of the hand fully opening Grip Patterns Thumb Opposed up to four grip patterns Thumb Non Opposed up to four g...

Страница 27: ...the user by a simple point and click in the relevant tables Opposed Primary This refers to selection of the initial two grip patterns available with the thumb in the opposed position The default grip...

Страница 28: ...age of an object is detected the finger position grip force is automatically altered to provide a more secure grip Electronic monitoring of this process occurs every 50ms Horizontal Buttons Restore De...

Страница 29: ...e screen The user will be required to follow steps outlined in section 5 8 to re connect the Bluetooth communication to the hand if further programming is needed Read from Hand This feature enables th...

Страница 30: ...as a green vertical bar with the peak signal indicated as single green line On closing the form the settings are retained for configuring the hand using the Send to Hand option The embedded animation...

Страница 31: ...wer the grip and current draw Note This has minimal effect on operation speed Speed Control Should you want to open or close the hand at less than maximum speed the numeric up down controls provide in...

Страница 32: ...32...

Страница 33: ...or right 6 0 Additional Information Warranty Repairs and Returns 6 1 Repairs 1 2 The clevis link has been designed to bend should the hand be excessively loaded during use If this should occur the par...

Страница 34: ...crew 7 8 Ensure that the finger flexes fully forward and springs back to the upright position as shown in the two images above Finished 3 4 Using a spare clevis link assembly from the tool kit Place i...

Страница 35: ...rd is monitored by a programme of internal and external audits All individual products are marked indicating that they comply with the requirements of the Medical Devices Directive 93 42 EEC MDD The m...

Страница 36: ...t may cause undesired operation of the device Under Industry Canada regulations this radio transmitter may only operate using an antenna of a type and maximum or lesser gain approved for the transmitt...

Страница 37: ...ulations this radio transmitter may only operate using an antenna of a type and maximum or lesser gain approved for the transmitter by Industry Canada To reduce potential radio interference to other u...

Страница 38: ...a passive Radio Frequency Identity Device to allow identification and trace during manufacture and in case of return to our bebionic service centres An extended warranty is available for the bebionic...

Страница 39: ...39...

Страница 40: ...nit 7 Hunslet Trading Estate Severn Road LEEDS LS10 1BL Tel 44 0 870 240 4133 Email customerservices steepergroup com www steepergroup com 3619 Paesanos Parkway Suite 200 San Antonio TX 78231 USA Tel...

Отзывы: