Restoring Set-Up Data for the CI-203CA Conveyor Attachment
“Conveyor Not Cal’ed <start>
To restore setup data in the conveyor, plug the CI-203 into the conveyor and switch on the conveyor
power. With the display showing, “Conveyor Not Cal’ed”, press start. Use the arrow keys to go to th
e
“setup” screen.
1.
Use arrow forward to “setup scanner”.
2.
Press “start”.
3.
This puts you in one of 3 scan windows.
While holding down the “save” key, press the “stop” key.
In this new screen, you have a series of items to check using the forward or back arrows. The
numerical values are to the right of the items.
For this particular instrument, please ensure that you have the following data which can be set using
the up and down arrow keys.
Precharge = ____
Scan width = ____
Scan time = _____
Step length = ____
After checking the above figures, press “stop” and “stop” again. If you have made changes, it will ask if
you want to save changes. Press “save”.
1.
Now you are back in the “setup scanner” window.
2.
Press “start”.
3.
Arrow up or down to the “manual scan” window.
4.
Press start.
5.
Then set threshold = ___.
Additionally, please ensure that the reflective tape surface for the laser on the conveyor is clean and
undamaged.