3
Technical Data
: GAS GRILL SH-9902-B, SH-9903-B, SH-183, SH-9904-B, SH-9905-B
The above mentioned Gas Grills are designed to operate at 2.8kPa on LPG
Gas consumption, pressures and injector-sizes are shown below:
Gas Grill SH-9902-B
Injector Orifice
Heat Output
Gas Consumption
I 3+(28-30/37), I 3B/P(30)
1.0
7kW
511g/h
Gas Grill SH-9903-B
Injector Orifice
Heat Output
Gas Consumption
I 3+(28-30/37), I 3B/P(30)
1.0
10.5kW
766g/h
Gas Grill SH-183
Injector Orifice
Heat Output
Gas Consumption
I 3+(28-30/37), I 3B/P(30)
1.15
15.8kW
1129g/h
Gas Grill SH-9904-B
Injector Orifice
Heat Output
Gas Consumption
I 3+(28-30/37), I 3B/P(30)
1.0
14kW
1022g/h
Gas Grill SH-9905-B
Injector Orifice
Heat Output
Gas Consumption
I 3+(28-30/37), I 3B/P(30)
1.0
17.5kW
1277g/h
Ignition: Push-button Piezo ignition system.
IMPORTANT:
Read the following instructions carefully and be sure your barbecue is properly installed,
assembled and cared for. Failure to follow these instructions may result in serious bodily
injury and/or property damage.
If you have any questions concerning assembly or operation, consult your dealer or LPG
Gas Company.
Never fit the cylinder under the barbecue in the housing always place the cylinder under
the side shelf at the end of the appliance or at the rear of the appliance. The cylinder
should be sited as far away from the appliance as possible without straining the hose.
IMPORTANT:
A suitable LPG Regulator that complies with the requirements of SANS 1237 must be
installed during the installation.
The appliance require an operating pressure of 2.8 kPa at the appliance. Do not use this
appliance with an adjustable regulator.
NOTE FOR CONSUMER: Retain this booklet for future Reference
Содержание SH-183
Страница 4: ...4 ...