BBG KDAEC 150 Скачать руководство пользователя страница 6

Hod 

USB 

communication 

is off Hold occurs 

when the 

 

key is pressed. 

Hold is released 

if 

  is 

pressed again or 

time expires as 

per Hti setting. 

USB print 

continuously. Hold 

occurs when the 

  key is 

pressed. Hold is 

released if 

  is 

pressed again or 

time expires as per 

Hti setting. 

USB prints and the hold 

occurs when 

  is 

pressed. If 

  is 

pressed a second time 

print will occur again. 

Hold is released if 

  is pressed again 

or time expires as per 

Hti setting. 

13.2 TECHNICAL PARAMETERS

 

The technical parameters allow adjusting of the scale for accuracy 

and speed. See the below for the complete list of parameters. 

 

Switch off the scale. 

 

Hold the 

 

key and then press 

 

momentarily. 

Release the 

 

key. The display shows the first technical 

parameter to set the filter “

FiL x

”. 

 

To exit the parameter setting at any time, press the 

 

key. 

 

To scroll through the technical parameters, press the 

 

key (which will advance to the next parameter). 

 

15 

3.3 SETTING UP 

 

NOTE: 

When moving the scale, take care to prevent bending of the cable and 

connector too much as over a period of time this can weaken the wires in the 

connector and cause malfunction.

 

 

4.0 KEYPAD 

 

Turns the scale on or off only   

 

Sends data via USB and combines with Hold functions, if 

enabled   

   

Selects kilograms, pounds, ounces or pounds-ounces   

 

Sets the display to true zero or net zero by storing the current 

weight in the tare memory   

Содержание KDAEC 150

Страница 1: ...KDAEC Instruction Manual KD AEC en V1 1 2011 ...

Страница 2: ... Now the display will show the AD count press the key to enter in the factory calibration 5 The display show ZERO clear the other things on the platform and the press the key to confirm Place the correct calibration mass as selected by the user at the centre of the pan and press the key to confirm until the scale return to the normal weighting mode 19 TABLE OF CONTENTS 1 0 INTRODUCTION 1 2 0SPECIF...

Страница 3: ...60 lb 16 oz x 5 oz Repeat ability 0 01 kg 0 02 lb 0 02 kg 0 05 lb 0 05 kg 0 1 lb 0 05 kg 0 1 lb 0 1 kg 0 2 lb Linearity 0 02 kg 0 04 lb 0 04 kg 0 1 lb 0 10 kg 0 2 lb 0 10 kg 0 2 lb 0 2 kg 0 4 lb 1 14 0 ERROR MESSAGES During the initial power on testing or during the operation the scale may show an error message The error messages are described below ERROR CODE DESCRIPTION POSSIBLE CAUSES nnnnn A c...

Страница 4: ...section contains critical calibration reference information and is protected by a Pin Code which can only be accessed by a qualified technician To exit the user must switch off the scale when the display shows Pi 17 I Platform size KDAEC 30kg 75kg 150kg 390 x310 x 40mm KDAEC M 30kg 75kg 150kg 200kg 300kg 500 x500 x40mm KDAEC L 75kg 150kg 200kg 300kg 900 x600 x40mm POWER supply 4 x1 5VAA battery DC...

Страница 5: ...gain or press the key 13 2 1 FILTER This parameter is for setting the speed of the display filter For poor environments the filter should be set at its slowest to minimise external influences on the scale For weighing small samples or gradual filling the filter should be set at a faster setting Press to scroll through the options The display will show FiL 1 to FiL 3 If it is set to FiL 1 then the ...

Страница 6: ...ete list of parameters Switch off the scale Hold the key and then press momentarily Release the key The display shows the first technical parameter to set the filter FiL x To exit the parameter setting at any time press the key To scroll through the technical parameters press the key which will advance to the next parameter 15 3 3 SETTING UP NOTE When moving the scale take care to prevent bending ...

Страница 7: ...ds the display for 15 1 x 15 seconds 3 Hti 2 Holds the display for 30 2 x 15 seconds 4 Hti 3 Holds the display for 45 3 x 15 seconds 5 Hti 4 Holds the display for 60 4 x 15 seconds Press the key to confirm the selection and move back tofirst parameter or press to exit the parameter setting HOLD AND PRINTING TABLE trn 1 trn 2 trn 3 Hod 1 USB communication is off Hold is off key has no function USB ...

Страница 8: ...le if the hold function 13 9 0 AUTO POWER OFF The auto power off can be set by the user to disable the feature or to apre set time interval See setting of the parameter in section 13 1 1 10 0 OPERATIONS 10 1 SWITCHING ON THE SCALE To switch on the scale press the key The display will show the software revision number and then flash all the digits and symbols before counting down to zero This ensur...

Страница 9: ... parameter 13 1 4 COMMUNICATION ADDRESS The fourth parameter is for setting the ID for the USB results output Display will show Add 0 DEFAULT SET This parameter sets the communication address which is sent via USB as an ID code There are 26 options to select from Add 0 to Add 25 Set Add 0 for no address The numbers relate to alphabets for example 1 A 2 B to 25 Y 13 1 5 SELECTION OF BAUD RATE The f...

Страница 10: ...ter the scale returns to zero 13 1 3 ENABLING OF UNITS The third parameter is to enable or disable the weighing units so that the user can select the enabled units during the weighing operation Display will show on kg DEFAULT SET 1 on kg Enables the unit 2 off kg Disables the unit Press the key to confirm the selection and move to the next 11 Normal OutputU See section 13 1 7 add A G W 2 00 cr lf ...

Страница 11: ...rror message CALEr will be displayed and the scale will return to zero Repeat the process correctly 9 Place the correct calibration mass as selected by the user at the centre of the pan Press the The display will return to weighing mode Note If the mass loaded is more than 20 of the factory calibration reference then an error message CALEr will be displayed and the scale will return to weighing wi...

Отзывы: