background image

7

1

2

3

4

1

2

3

4.3   Mounting the contact profile onto the mounting profile

4.4   Mounting end caps

Fit the first side of the 
contact profile flush at both 
ends of the mounting profile 
and apply uniform pressure 
to press it into the mounting 
profile, working from the 
ends towards the centre.

Prepare the lower end cap: 
remove the drainage stud

The rubber retainers must engage fully in the mounting 
profile. 

Tip: 

Use a tool to help you to push the retainers in. Use 

the curved edge to roll over the retainers, applying slight 
pressure.

Push on the profile hard from the front to check 
that it has been pressed in correctly. The contact 
profile must not come away from the  
mounting profile at any point.

Turn out the end cap at the top

Pull the hole over the retainer on the 
contact end piece

Tip: 

In case of limited accessibility, the first side of the contact profile can be fitted into the mounting profile prior to fixing the mounting profile. 

This can be helpful for example at folding or swing gates, when sensors are mounted near the ground.

Always work from both ends 
towards the centre when 
pushing in the profile.  
This prevents unwanted 
elongation of the rubber 
profiles.

Содержание ExpertSystem XL-CP42A24 Series

Страница 1: ...re that the power supply is disconnected Cover any neighbouring live parts or remove them Before switching on the power supply check the wiring as a precaution to prevent any damage or malfunction aff...

Страница 2: ...end pieces connection cables and resistor plugs are packaged separately and must remain inside their original packaging until used The components must be stored in a dry location Storage temperatures...

Страница 3: ...ensor Rubber profile cutters XL Cut Risk of injury Follow the safety instructions for the cutting device 3 4 Assembly of contact profiles 1 Cutting the XL contact profile to length 2 Mounting contact...

Страница 4: ...and re assembly The sealant is highly adhesive dust and dirt particles will stick to it immediately on contact Therefore once you have unpacked a contact end piece and removed the protective cover yo...

Страница 5: ...1 Cutting the mounting profile to length 4 Mounting ExpertSystem XL sensors Mounting profiles punched for quick fastening XL APxQ Mounting profiles solid XL APx Always cut at right angles Lmounting p...

Страница 6: ...the clips as far as it will go To prevent damage place a suitable piece of wood between the mounting profile and the hammer do not hammer directly onto the face of the profile Never drive in the sens...

Страница 7: ...over the retainers applying slight pressure Push on the profile hard from the front to check that it has been pressed in correctly The contact profile must not come away from the mounting profile at...

Страница 8: ...when carrying out subsequent installation and commissioning work 8 Contact Position the end cap and pull it over the profile Position the fastening clip and push it in as far as it will go Correct end...