6
max.
80 mm
50 mm
12 mm
33 mm
5 mm
max.
80 mm
max.
500 mm
max.
500 mm
max.
500 mm
max.
500 mm
max.
500 mm
max.
500 mm
max.
500 mm
4.2 Mounting the mounting profile
The mounting profile must be mounted on a flat surface.
1. Use XL-QFIX screws to secure the
XL-QME quick-fastening clips firmly in
place, as shown in the illustration.
2. Hook the prefabricated sensors into
the mounted fastening clips.
3. Using a plastic hammer and a mode-
rate degree of force, drive the
mounting profile into the teeth in the
clips as far as it will go. To prevent
damage, place a suitable piece of
wood between the mounting profile
and the hammer; do not hammer
directly onto the face of the profile.
Never drive in the sensor with the end
cap attached! If an end cap has
already been attached along with its
fastening clip, loosen and fold it back
from the mounting profile, then
perform the mounting work specified
in points 2 and 3. Re-attach the end
plug once you have finished.
Hole pattern
100 mm
Mounting with quick-fastening system
Mounting with screws
Use pan head or countersunk screws
Ensure that any additional holes required for the cable routing are provided in the mounting profiles and door profiles.