www.baytex.co.nz
6/18
SIMPLICITY - PERFORMANCE - STYLE
10m Square Frame Marquee
On Ground - Staking / Ballasting Options
21 Dec 2021
80.110.500 10m SQ Assembly Manual.vwx
1200 nominal
2500kg
load binder
For Max. Capacity
Pegs Must be
Driven Vertically
A
x2 Stakes
per Base Foot
A
B
D
0km/h
10km/h
20km/h
30km/h
40km/h
50km/h
60km/h
70km/h
80km/h
90km/h
120km/h
Wind Speed
Recommended Staking Options. Based on average Soil Conditions.
Minimum ground bearing capacity 50kpa.
Consider Location factors
eg: on Exposed Hilltop, limit speed to 50% of above.
In poor soil use more stakes or longer stakes.
Guy options: 10mm Nylon Rope or 50mm Ratchet Loadbinders
Over 50km/h - All Walling to be fitted and closed
For Wind Speeds over engineered solution - All Fabric to be Removed from Frame. Frame may be left standing
780kg Ballast
Typical Stake Capacity
250kg in average soil
conditions
700
780kg Ballast
0.7m x 0.7m x 0.7m
Concrete Block.
Tied to base with sole plate
700
700
Nominal Stake
Capacity 250kg.
2 Stakes per base.
1.5 x safety factor.
engineered
engineered
engineered
Minimum Staking for each Leg of typical 10m x 5m Bay
Stake Options:
- Peg Ø25 x850mm
minimum 650mm
embedment
- Earth Anchor PE18-33
Ø33 x 460mm
minimum 430
embedment
B
Ballast 780kg
per Base Foot
attach to Foot
and Shoulder
Connector
C
x2 Stakes
per Base Foot
x3 Stakes
per Base Foot
with Bracing
C
engineered
100km/h
110km/h
Nominal Stake
Capacity 250kg.
2 Stakes per base.
1.5 x safety factor.
3 Stakes per base
with Bracing
Knee Braces
Required
108km/h
75km/h
95km/h
D
x3 Stakes
per Base Foot
x4 Stakes
per Base Foot
with Bracing
x2 PE26
Earth Anchor
with pegging
plate and
2.5t Guy
per shoulder
Nominal Stake
Capacity 250kg.
3 Stakes per base.
4 Stakes per base
with Bracing
x2 PE26
Earth Anchor
with pegging plate
and 2.5t Guy
per shoulder
Wall Barce Cables
Required