20
For example, if the PDI is installed in a non-cascaded unit as Module 2 and you are
using the default port select code ($BT), send
$BT2<cr>$CONFIG<cr>
to enter
into configuration mode. No characters should be typed between $BT2<cr> and
$CONFIG<cr>. If this happens, the entire configuration sequence will be
discarded and you will have to send the configuration sequence again.
NOTE:
All commands must be in uppercase.
To access the menu-driven configuration mode of the PDI from the service port,
use the following procedure:
1.
Connect a terminal to the
EIA-232
service port and configure the
terminal's serial parameters to 9600 baud rate, 8 word size, 1 stop bit, and
no parity.
2.
Connect to the PDI by sending
$BAYTECH
, the desired module number (2
to 16), and
Carriage Return
or
Line Feed
.
3.
Access configuration mode by sending
$CONFIG<cr>
. Following the
example on the previous page, you would send
$BAYTECH2<cr>$CONFIG<cr>
to configure Module 2.
NOTE:
All commands must be in uppercase.