![Bayliner Ciera Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/bayliner/ciera/ciera_user-manual_2712971016.webp)
10 Chapter 2: Components/Systems
3055 EL Ciera Sunbridge • Owner’s Manual Supplement
Connecting To Shore Power
1.
Monitor the AC panel’s polarity indicator
lights as follows:
• A green light illuminating after the
power cord is plugged into the boat’s
external power receptacle indicates
acceptable electrical power. You may
energize the master breaker switch.
• A red light, however, indicates
reversed polarity, which could cause
electrical system damage and possibly
electrical shock injuries. In this case,
do not energize the master breaker
switch (see previous warning).
2.
Activate the AC system by turning
the ship/shore master breaker to the
dockside position.
3.
Turn on the master breaker and individ-
ual component breakers as required.
FIRE, EXPLOSION & SHOCK HAZARD!
• Do not alter shore power connectors and use only compatible connectors.
• Before connecting to shore power, ensure all breakers and switches on the AC master
panel are in the off position.
• To prevent shock or injury from an accidental dropping of the “hot” cord into the water,
always attach the shore power cord to the boat inlet first; then to the dockside connection.
When disconnecting the shore power cable, always disconnect the shore power cable at the
dockside outlet first.
• Close the shore power inlet cover tightly when not in use.
DANGER!
!
SHOCK & ELECTRICAL SYSTEM DAMAGE HAZARD!
•
Ν
ever connect dockside power to your boat outside North America unless you have pur-
chased the international electrical conversion option.
• The simultaneous use of several AC components can result in an overloaded circuit. It
may be necessary to turn off one or more accessories in order to use another accessory.
• Use double insulated or three-wire protected electrical appliances whenever possible.
• Never switch the AC panel’s master breaker to the generator position while connected to
shore power.
CAUTI O N!
!
SHOCK & ELECTRICAL SYSTEM DAMAGE HAZARD!
• You must monitor the polarity indicator lights every time you connect to shore power.
• When connecting to shore power and you encounter a reversed polarity light (red col-
ored), do not energize the main breaker switches. Instead, immediately disconnect the
shore power cord from the dockside receptacle first and notify marina management.
WARN I NG!
!
RED
GRN
RED
GRN
LOCKOUT
LOCKOUT
AC VOLTS
GENERATOR
AC PANEL (SHOWN WITH OPTIONAL SHORE POWER INLET)
Содержание Ciera
Страница 1: ......
Страница 6: ......
Страница 36: ...30 Appendix A Wiring Schematics 3055 EL Ciera Sunbridge Owner s Manual Supplement Dash Connector Harness...
Страница 37: ...Appendix A Wiring Schematics 31 3055 EL Ciera Sunbridge Owner s Manual Supplement Hull Harness...
Страница 38: ...32 Appendix A Wiring Schematics 3055 EL Ciera Sunbridge Owner s Manual Supplement Hull Harness Diesel Option...
Страница 39: ...Appendix A Wiring Schematics 33 3055 EL Ciera Sunbridge Owner s Manual Supplement Deck Harness...
Страница 40: ...34 Appendix A Wiring Schematics 3055 EL Ciera Sunbridge Owner s Manual Supplement AC Dockside Harness...
Страница 49: ...Owner s Notes...
Страница 50: ...Owner s Notes...
Страница 51: ......
Страница 52: ...Part Number 79555 Bayliner P O Box 9029 Everett WA 98206 360 435 5571...