13
Infeed Conveyor
Both the inlet (INFEED) and the outlet (OUTFEED) conveyors are powered by switches on the control box. The Active position will be indicated by the switch turning green.
INFEED CONVEYOR
The INFEED conveyor can be run in two modes:
MANUAL and AUTO
.
MANUAL MODE
The conveyor will run continuously until the switch is manually turned to the OFF position. It does not utilize the high level or low level sensors to operate.
AUTO MODE
The conveyor will start running if the low level sensor does not detect seed in the hopper and until the seed “head” reaches the high level sensor, then will shut off automatically.
It will re-start once the low level sensor no longer detects seed present.
Outfeed Conveyor
The OUTFEED conveyor runs when the switch is manually turned to the ON position and stopped when manually turned to the OFF position.
There is no automatic ON/OFF operation of the OUTFEED conveyor.