Step 3:
Set the empty Calibration Cylinder on the Scale and
touch the
ZERO
button to zero out the Scale.
• The digital readout should display
0.00
value.
Application Rate Options
Determine the Liquid to Seed Application rate.
• Read the treatment product label for the application rate per CWT (100 pounds) of seed...
Example: 5 ounces of treatment/cwt of seed at a dilution rate of 1:1 with water equals 10 ounces/cwt of total treatment.
• RATE:
If listed in ounces, convert to ml (1 oz = 29.6 ml)...
Example: 10 ounces x 29.6 cc/ounce =296 ml
• RATE:
If listed in ml/pound, divide ml rate of treatment/cwt of seed by 100...
Example: 296 ml/cwt ÷ 100 lbs = 2.96 ml/lbs
• RATE:
If listed in ml of treatment/minute, multiply ml of treatment/pound of seed by lbs of seed/minute...
Example: 2.96 ml/lbs. x 400 lbs/minute = 1,184 ml per minute.