13
OPTO-SENSORS:
Used at all pockets on target board, they are Omron Opto-interrupters (P/N: 800773-3). They are located
on a rail and two small brackets, on the underside of the target board. This part is also used for the ball
count and ball release functions.
SINGLE BALL RELEASE ASSEMBLY:
Located on underside of the right side channel cover. It has a solenoid connected via linkage to a release
arm. Upon start of the game the solenoid engages and allows the balls to roll down to the player. The
Ball Release Sensor, which is mounted in front of this assembly, counts the balls as they are being
released. After counting the appropriate amount of balls, the solenoid disengages and is able to prevent
any more balls from being released due to the pressure applied by the springs. Example: The game is
typically set for 9 balls per play but you may only have 1 ball loaded into the game. In this case, solenoid
will engage to allow the ball to pass until the sensor detects the 9 balls and will then immediately
disengage.