BILL ACCEPTOR DIAGNOSTICS
Note: There are many different models and brands of Bill Acceptors that are used on redemption games.
Your Bill Acceptor may differ from the unit shown. An up-stacker should be used for clearance issues.
Standard DBA is MEI # AE2431-D5E Part # A5AC9091
Determine if Bill Acceptor has power:
Turn game ON—The bill acceptor should make noise as
stacker cycles and green lights on outside bezel should
flash.
If NO power:
Use meter to measure 110 AC voltage at cable going into Bill A
cceptor from power strip.
If power is OK:
Clean Bill Acceptor path to make
sure there is nothing jamming unit. Check dipswitch settings on
side of acceptor.
Make sure switch # 8 is OFF for Always Enable
ERROR CODES
Count the number of flashes on front bezel
of Bill Acceptor and follow chart for repair